.jpg)
|
|
25
- 300 lb. |
|
.jpg)
|
|
500
- 5000 lb. |
These
load cells are environmentally sealed, temperature-compensated strain gage
sensors capable of highly accurate, highly reliable force measurement
under the toughest laboratory and industrial conditions.
They
demonstrate exceptional structural resistance to damage or measurement
error ("crosstalk") from off-axis loading, side loading, and
other extraneous forces and bending moments
("eccentric" loading can
also arise from unlevel mounting or thermal expansion of supporting
structures. The table below lists 400 Series Limit
Load Values for static application. These are maximum
extraneous forces and moments that can be applied singly and
simultaneously with half the nominal load capacity without causing
transducer damage or a permanent shift of zero or calibration.
Actual measurement errors ("crosstalk") for each of the limit
values tabulated are typically less then 0.2% of the rated (full-scale)
output. NOTE: Load cells are designed to respond only to the force
component parallel to the loading axis.).
Unique
flexure designs, using low deflection values and premium alloy materials,
give exceptional fatigue life, plus excellent linearity and hysteresis
characteristics. Optional dual bridge is available on request.
All
400 Series transducers may be used in both tension and compression.
Standard models in stock cover nominal ranges from ±25 through ±5000
pounds, with smaller or larger ranges available on special order.
All models incorporate sealed barometrically compensated construction, and
exhibit a typical zero shift of less then 0.2% of full scale for ambient
pressure changes of ±2 psi.
Individually
tested and calibrated in both tension and compression, each 400 Series
transducer is supplied with both "mV/V" and shunt-resistor
calibration data, traceable to the National Bureau of Standards.
General Specifications are
given below, as are specifications for Load Cell
Accessories that may be used with the 400 Series.
|
Load
Cell
Model |
Nom.
Load
Capacity*
(lb. / N) |
Ringing
Frequency**
(Hz) |
Limit
Loads |
Bending
Moment (M)
(lb.-in. / N-m) |
Shear
(S)
(lb. / N) |
Torque
(T)
(lb.-in. / N-m) |
|
400-25 |
±25
±125 |
2100 |
150
17 |
150
667 |
40
4.5 |
|
400-50 |
±50
±200 |
2800 |
150
17 |
150
667 |
40
4.5 |
|
400-100 |
±100
±500 |
3800 |
180
20 |
250
1100 |
40
4.5 |
|
400-200 |
±200
±1000 |
5400 |
180
20 |
250
1100 |
40
4.5 |
|
400-300 |
±300
±1500 |
7000 |
180
20 |
250
1100 |
40
4.5 |
|
400-500 |
±500
±2000 |
1600 |
2800
316 |
1400
6200 |
1100
124 |
|
400-1K |
±1000
±5000 |
2000 |
3900
441 |
2000
8900 |
1100
124 |
|
400-2K |
±2000
±10000 |
3200 |
5000
565 |
2800
12500 |
1100
124 |
|
400-3K |
±3000
±15000 |
4100 |
5500
621 |
3400
15100 |
1100
124 |
|
400-5K |
±5000
±20000 |
5000 |
5500
621 |
4200
18700 |
1100
124 |
|
*
Metric rating approximate only.
** Calculated or determined by test with no external force or
load. |
General
400 Series Specifications [Top
]
|
|
Dimensions
(in. / cm) for Models 400-25 through 400-300 |
|

|
|
Dimensions
(in. / cm) for Models 400-500 through 400-5K |
|

|
|
Deflection
at Nominal Load Limit |
Models
400-25 through 400-300: ±0.003 in. (±0.008
cm)
Models 400-500 through 400-5K: ±0.005 in. (±0.013 cm) |
|
Bridge |
Four-arm
bonded foil gages, 350
Ω nominal |
|
Number
of Bridges |
1
or 2 |
|
Insulation
Resistance, Bridge/Case |
Greater
than 5000 MΩ at 50 VDC |
|
Excitation |
20
V maximum, DC or AC (RMS) |
|
Output
(nominal) |
Models
400-25 through 400-300: 2 mV/V ±
0.25% of full scale
Models 400-500 through 400-5K: 3 mV/V ±
0.25% of full scale |
|
Zero
Balance |
±1.0%
of full scale |
|
Linearity
and Hysteresis |
Models
400-25 through 400-300: ±0.05% of full scale, max.
Models 400-500 through 400-5K: ±0.10% of full scale, max. |
|
Repeatability |
Models
400-25 through 400-300: ±0.02% of full scale
Models 400-500 through 400-5K: ±0.05% of full scale |
|
Overload
Capacity |
150%
of nominal rating (static) |
|
Compensated
Temperature Range |
+70° F to
+170° F (+21°
C to +77° C) |
|
Operating
Temperature Range |
-65° F to
+200° F (-54°
C to +93° C) |
|
Fatigue
Life |
100
million cycles at 0 to 50% of nominal rating (minimum);
50 million cycles at +50% to -50% of nominal rating (minimum) |
|
Load
Cell Accessories
[Top
]
|
|
Load
Buttons
|
|
|
"A"
(in.) |
"B"
(in.) |
"C"
Thread
(in.) |
"R"
(in.) |
| 17/32 |
3/8 |
1/4
- 28 |
1.0 |
| 3/4 |
3/8 |
1/4
- 20 |
2.0 |
|
|
Rod
Ends
|
|
|
"A"
(in.) |
"B"
(in.) |
"C"
Bore
(in.) |
"D"
(in.) |
| 1 |
1.562 |
0.2500 |
3/4 |
| 1
1/2 |
2.438 |
0.500 |
1
5/16 |
"W"
(in.) |
Thread
(in.) |
| 0.375 |
1/4
- 28 |
| 0.625 |
1/4
- 20 |
|
|
Load
Platform
|
|
|
May be used with all
models of the 400 Series, 434A Series,
and 434AM Series.
"A"
(in.) |
"B"
(in.) |
"C"
(in.) |
| 2.652 |
0.625 |
0.250 |
| 3.125 |
0.937 |
0.312 |
"D"
(in.) |
"E"
Thread
(in.) |
| 0.500 |
1/4
- 28 UNF |
| 0.750 |
1/2
- 20 UNF |
|
|