General
512 Series Specifications [Top
]
|
|
Measurement
Type |
True
Gage* or Absolute |
|
Measured
Fluids |
Gas,
liquid |
|
Case
and Wetted Parts Material |
17-4
PH Stainless |
|
Bridge |
Four-arm
bonded foil gages, 350 Ω nominal |
|
Insulation
Resistance to Ground |
5000 MΩ at 50 VDC |
|
Excitation |
10
VDC (calibration); up to 12 VDC or AC acceptable |
|
Output
(standard)** |
3
mV/V |
|
Resolution |
Infinite |
|
Accuracy |
±0.25% of full scale |
|
Linearity |
±0.15% of full scale |
|
Hysteresis |
±0.10% of full scale |
|
Repeatability |
±0.05% of full scale |
|
Overload
(safe) |
50%
over capacity |
|
Burst
Pressure |
Models
512-10(G,A) through 512-5000(G,A): 300% over capacity
Models 512-7500(G,A) through 512-10000(G,A): 200% over
capacity |
|
Dead
Volume |
Models
512-10(G,A) and 512-15(G,A): 0.25 cubic inch
Models 512-25(G,A) through 512-1500(G,A): 0.17 cubic inch
Models 512-2000(G,A) through 512-10000(G,A): 0.12 cubic inch |
|
Temperature
Coefficient (Zero and Span) |
±0.005% of full scale/°F
(±0.009% of full scale/°C) |
|
Compensated
Temperature Range |
+60° F to
+160° F (+16°
C to +71° C) |
|
Operating
Temperature Range |
-100° F to
+325° F (-73°
C to +163° C) |
|
Weight
(nominal) |
10
oz. (283 g) |
|
*
Gage pressure units greater than 500 psi (35 bar) are sealed at
atmospheric pressure.
** Optional 0-5 VDC or 4-20 mA output is available (contact
the factory for details). |