Designed
for use while submerged under fresh water and most other non-corrosive
liquids and gases, these LVDT's are extensively used in industrial and
R&D applications. They are designed to operate in pressures of
up to 10 bar using the standard connector (optional electrical
terminations allow up to 206 bar).
The
welded stainless-steel body is hermetically sealed and has a cable exit
which is double-sealed using an internal rubber gland plus a polyolefin
shrink tube covering the cable and transducer body. An alternative
MI stainless-steel sheathed cable option is available for use under high
liquid pressures (as in soil testing apparatus, hydraulics, vessel
studies, etc.)
General Specifications are
given below.
Go
to LVDT SELECTION GUIDE
|
DC
"SUM" Series
|
|

|
|
Dimension
"X" is at the Electrical Zero Position |
|
LVDT
Model |
Nom.
Linear
Range
(in. / mm) |
Dimensions
(in. / mm) |
Total
Weight
(oz. / g) |
| "L" |
"X" |
"D" |
"A" |
|
DSD200SUM |
±0.1
±2.5 |
2.68
68 |
1.3
33 |
0.813"
(13/16")
20.6 |
2.44
62 |
11
306 |
|
DSD400SUM |
±0.2
±5 |
|
DSD600SUM |
±0.3
±7.5 |
|
DSD800SUM |
±0.4
±10 |
|
General
DC "SUM" Specifications [Top
]
(See
also the statement
on LVDT specifications)
|
|
Supply
Requirements, SINGLE* |
Using
±5 VDC Output: +20 to +40 VDC, 30 mA
Using 0-10 VDC Output: +24 to +40 VDC, 30 mA |
|
Supply
Requirements, DUAL |
Using
±5 VDC Output: ±10 to ±20 VDC, 30 mA
Using 0-10 VDC Output: ±12 to ±20 VDC, 30 mA |
|
Armature |
UNGUIDED |
|
Linearity
(% error of full scale, worst case) |
±0.5%** |
|
Standard
Output (in/out) |
-5
to +5 VDC (+0%, - 5%) or 0 to +10 VDC (+0%, - 5%) |
|
Output
Fluctuation with Supply Fluctuation |
±5
VDC Output: 1.25 mV/V, typical
0-10 VDC Output: 5 mV/V, typical |
|
Output
Load (minimum) |
±5
VDC Output: 2 kΩ
0-10 VDC Output: 2 kΩ (10 kΩ when supply < 26 V) |
|
Output
Ripple |
30
mV peak-to-peak |
|
Output
Bandwidth (electrical) |
200
Hz (flat) |
|
Output
Impedance |
2
Ω |
|
Temperature
Coefficient (Zero and Span) |
±0.01%
of full scale/°C (±0.005% of full scale/°F) |
|
Operating
Temperature Range |
-51°
C to +80° C (-60° F to +176° F) |
|
Electrical
Termination |
6.5
ft. (2 m) shielded cable*** |
|
*
Must be floating with respect to output.
** ±0.25% and ±0.1% linearity are optional on some models (contact
the factory for details).
*** Longer cable available to order; alternative electrical
termination optional (contact
the factory). |
|