SEARCH

Products
Index

See List

Selection Guide

Applications

Support

Downloads

Reference

Contact Us

HOME

2000 Series
3000 Series
3KPlus Series
3500 Series
4000 Series
5D Series
System 10
MeasuringPad
SPS6000
SPS8000
Cards
Transducers
Software


[Top

    

 

Back to Transducer MODELS
(Go here to ORDER
THESE PRODUCTS)

 

Back to LVDT GENERAL PAGE

   
DC-Operated, Short-Stroke
Unguided Armature
 

"SU5" High-Voltage LVDT Series (DC)

These DC-EXCITED SHORT-STROKE LVDT models with UNGUIDED ARMATURE operate from a simple unregulated power supply to generate two high-level output signals: ±5 VDC and 0-10 VDC.  For standard-output versions, see the "SU" LVDT Series.  For hermetically sealed versions, see the DC "SUM" LVDT Series

Each model includes high-quality electronics for energization and signal conditioning.  Encapsulated, integrated electronics are suitable for operation in harsh industrial environments.  All models are fitted with 2 meters (6.6 ft.) of shielded cable. 

General Specifications are given below.

Go to LVDT SELECTION GUIDE


DC "SU5" Series  [Back ]

Dimension "X" is at the Electrical Zero Position

LVDT
Model

Nom.
Linear
Range
(in. / mm)

Dimensions (in. / mm) Arma-
ture
Weight
(oz. / g)
Total
Weight
(oz. / g)
Inward
Over-
travel
(in /
mm)*
"L" "X" "D1" "D2" "ID"

DSD200SU5

±0.1
±2.5

2.52
64
1.28
32.5
0.813
20.6
0.08
2
0.1
2.54
0.1
2.9
2.9
83
0.46
11.7

DSD400SU5

±0.2
±5

0.36
9.2

DSD600SU5

±0.3
±7.5

0.26
6.7

DSD800SU5

±0.4
±10

0.17
4.2

* Outward overtravel is not applicable.

 

General DC "SU5" Specifications  [Top ]

(See also the statement on LVDT specifications)

Supply Requirements, SINGLE*

Using ±5 VDC Output: +20 to +40 VDC, 30 mA
Using 0-10 VDC Output: +24 to +40 VDC, 30 mA

Supply Requirements, DUAL

Using ±5 VDC Output: ±10 to ±20 VDC, 30 mA
Using 0-10 VDC Output: ±12 to ±20 VDC, 30 mA

Armature

UNGUIDED

Linearity (% error of full scale, worst case)

±0.5%**

Standard Output (in/out)

-5 to +5 VDC (+0%, - 5%) or 0 to +10 VDC (+0%, - 5%)

Output Fluctuation with Supply Fluctuation

±5 VDC Output: 1.25 mV/V, typical
0-10 VDC Output: 5 mV/V, typical

Output Load (minimum)

±5 VDC Output: 2 kΩ
0-10 VDC Output: 2 kΩ (10 kΩ when supply < 26 V)

Output Ripple

30 mV peak-to-peak

Output Bandwidth (electrical)

200 Hz (flat)

Output Impedance 

2 Ω

Zero Temperature Coefficient 

±0.01% of full scale/°C (±0.005% of full scale/°F)

Span Temperature Coefficient 

±0.03% of full scale/°C (±0.015% of full scale/°F)

Operating Temperature Range

-51° C to +80° C (-60° F to +176° F)

Electrical Termination

6.5 ft. (2 m) shielded cable

* Must be floating with respect to output.

** ±0.25% and ±0.1% linearity are optional on some models (contact the factory for details).

[Top ]
 
 

© 1996, 2002 Daytronic Corporation