SEARCH

Products
Index

See List

Selection Guide

Applications

Support

Downloads

Reference

Contact Us

HOME

2000 Series
3000 Series
3KPlus Series
3500 Series
4000 Series
5D Series
System 10
MeasuringPad
SPS6000
SPS8000
Cards
Transducers
Software


[Top

    

 

Back to Transducer MODELS
(Go here to ORDER
THESE PRODUCTS)

 

Back to LVDT GENERAL PAGE

 

DC-Operated, Long-Stroke
Unguided Armature

 

"LU2" Low-Voltage LVDT Series (DC)

These are DC-EXCITED LONG-STROKE LVDT models with UNGUIDED ARMATURE, for use in low-voltage applications.  They may be used, for example, with digital panel meters to form a complete readout system.

Unlike the standard DC "LU5" LVDT Series, the DC "LU2" LVDT's operate from either a +5 VDC regulated supply or a +6 to +18 VDC unregulated supply.  Each LVDT generates a single output signal of ±2 VDC that is electrically isolated from the input voltage.

All models are fitted with 2 meters (6.6 ft.) of shielded cable.  

General Specifications are given below.

Go to LVDT SELECTION GUIDE


DC "LU2" Series

Push rod diameter (shown as "D2") is 0.19 in. (4.75 mm) for all models;
armature diameter (inside transducer) is 0.24 in. (6 mm) for all models

LVDT
Model

Nom.
Linear
Range
(in. / mm)

Dimensions (in. / mm) Arma-
ture
Weight
(oz. / g)
Total
Weight
Inward
Over-
travel
(in /
mm)*
"L" "X" "A" "D1" "ID"

DSD1000LU2

±0.5
±12.5

6.9
175
1.7
43
0.35
9
0.813
20.6
0.27
6.8
0.6
17
7.6 0z.
216 g
0.91
23

DSD2000LU2

±1
±
25

7.9
200
2.7
69
0.81
23
9.5 oz.
270 g
0.89
22.5

DSD4000LU2

±2
±50

12.5
317
3.2
81
1.3
37
13.4 oz.
382 g
0.62
15.8

DSD6000LU2

±3
±75

16.9
430
4.7
119
1.94
55
1.1 lb.
497 g
0.98
25

DSD8000LU2

±4
±100

18.6
472
5.2
132
2.5
71
1.35 lb.
625 g
0.73
18.6

DSD12000LU2

±6
±150

26.1
663
7.2
183
3.5
100
1.87 lb.
852 g
0.75
19

DSD16000LU2

±8
±
200

33.6
854
10.2
259
4.9
140
2.75 lb.
1250 g
1.04
26.5

* Outward overtravel is not applicable.

 

General DC "LU2" Specifications  [Top ]

(See also the statement on LVDT specifications)

Supply Requirements

+5 VDC regulated or +6 to +18 VDC unregulated; 100 mA

Armature

UNGUIDED

Linearity (% error of full scale, worst case)

±0.5%*

Output

±2.2 VDC nominal, isolated from supply

Output Load (minimum)

2 kΩ

Output Ripple

30 mV peak-to-peak

Output Bandwidth (electrical)

200 Hz

Output Impedance 

2 Ω

Zero Temperature Coefficient 

±0.01% of full scale/°C (±0.005% of full scale/°F)

Span Temperature Coefficient 

±0.03% of full scale/°C (±0.015% of full scale/°F)

Operating Temperature Range

-51° C to +71° C (-60° F to +160° F)

Electrical Termination

6.5 ft. (2 m) shielded cable

* ±0.25% and ±0.1% linearity are optional on some models (contact the factory for details).

[Top ]
 
 

© 1996, 2002 Daytronic Corporation