These
are DC-EXCITED LONG-STROKE LVDT models with CAPTIVE
ARMATURE, for use in low-voltage applications. They may be used,
for example, with digital panel meters to form a complete readout system.
Unlike
the standard DC "LC5" LVDT Series,
the DC "LC2" LVDT's operate from either a +5 VDC regulated
supply or a +6 to +18 VDC unregulated supply. Each LVDT
generates a single output signal of ±2 VDC that is electrically
isolated from the input voltage.
All
models are fitted with 2 meters (6.6 ft.) of shielded cable.
General Specifications are
given below.
Go
to LVDT SELECTION GUIDE
|
DC
"LC2" Series
|
|

|
|
REAR
MOUNT: M5 x 0.8 female, 0.43 in. (11 mm) deep
FRONT MOUNT: M5 x 0.8, 0.59 in. (15 mm) long |
|
LVDT
Model |
Nom.
Linear
Range
(in. / mm) |
Dimensions
(in. / mm) |
Body
Weight |
Overtravel
(in. / mm) |
| "L" |
"X" |
"A" |
"D1" |
Inward |
Outward |
|
DSD1000LC2 |
±0.5
±12.5 |
7.5
191 |
1.5
38 |
0.91
23 |
0.813
20.6 |
12
oz.
384 g |
0.51
13 |
0.42
10.6 |
|
DSD2000LC2 |
±1
±25 |
8.5
216 |
2.5
63 |
13.8
oz.
390 g |
0.51
13 |
0.39
10 |
|
DSD4000LC2 |
±2
±50 |
13.1
333 |
3.0
76 |
1.13
lb.
511 g |
0.39
10 |
0.55
14 |
|
DSD6000LC2 |
±3
±75 |
17.5
445 |
4.5
114 |
1.38
lb.
625 g |
0.94
24 |
0.59
15 |
| DSD8000LC2 |
±4
±100 |
19.3
490 |
5.0
127 |
1.69
lb.
767 g |
0.31
8 |
0.55
14 |
| DSD12000LC2 |
±6
±150 |
26.8
681 |
7.0
178 |
2.25
lb.
1022 g |
0.48
12.3 |
0.68
17.2 |
| DSD16000LC2 |
±8
±200 |
34.3
871 |
10.0
254 |
3.2
lb.
1448 g |
0.87
22 |
0.98
25 |
| DSD20000LC2 |
±10
±250 |
42.0
1067 |
12.0
305 |
3.7
lb.
1676 g |
1.34
34 |
1.38
35 |
| DSD30000LC2 |
±15
±375 |
58.0
1473 |
16.0
406 |
4.9
lb.
2215 g |
0.49
12.5 |
0.5
12.5 |
| DSD37000LC2 |
±18.5
±470 |
68.5
1740 |
20.0
508 |
5.8
lb.
2613 g |
0.2
5 |
1.30
33 |
|
General
DC "LC2" Specifications [Top
]
(See
also the statement
on LVDT specifications)
|
|
Supply
Requirements |
+5
VDC regulated or +6 to +18 VDC unregulated; 100 mA |
|
Armature |
CAPTIVE
(GUIDED) |
|
Linearity
(% error of full scale, worst case) |
±0.5%* |
|
Output |
±2.2
VDC nominal, isolated from supply |
|
Output
Load (minimum) |
2
kΩ |
|
Output
Ripple |
30
mV peak-to-peak |
|
Output
Bandwidth (electrical) |
200
Hz |
|
Output
Impedance |
2
Ω |
|
Zero
Temperature Coefficient |
±0.01%
of full scale/°C (±0.005% of full scale/°F) |
|
Span
Temperature Coefficient |
±0.03%
of full scale/°C (±0.015% of full scale/°F) |
|
Operating
Temperature Range |
-51°
C to +71° C (-60° F to +160° F) |
|
Electrical
Termination |
6.5
ft. (2 m) shielded cable |
|
*
±0.25% and ±0.1% linearity are optional on some models (contact
the factory for details). |
|