Designed
for use while submerged under fresh water and most other non-corrosive
liquids and gases, these LVDT's are extensively used in industrial and
R&D applications.
The
stainless-steel body is hermetically sealed and has a cable exit
which is double-sealed using an internal rubber gland plus a polyolefin
shrink tube covering the cable and transducer body. An alternative
MI stainless-steel sheathed cable option is available for use under high
liquid pressures (as in soil testing apparatus, hydraulics, vessel
studies, etc.)
General Specifications are
given below.
Go
to LVDT SELECTION GUIDE
|
AC
"SUM" Series
|
|

|
|
Dimension
"X" is at the Electrical Zero Position |
|
LVDT
Model |
Nom.
Linear
Range
(in. / mm) |
Dimensions
(in. / mm) |
Arma-
ture
Weight
(oz. / g) |
Total
Weight
(oz. / g) |
Nom.
Sensiti-
vity
(V/V
at f.s.) |
| "L" |
"X" |
"D" |
"T" |
|
DS80SUM |
±0.04
±1 |
1.82
46.35 |
0.69
17.4 |
0.315
8 |
0.50
12.7 |
0.05
1.3 |
0.7
20 |
0.07 |
|
DS200SUM |
±0.1
±2.5 |
2.07
52.5 |
0.77
19.5 |
0.374
9.5 |
0.55
14 |
0.05
1.4 |
1.0
28 |
0.19 |
|
DS400SUM |
±0.2
±5 |
2.17
55 |
1.04
26.5 |
0.374
9.5 |
0.73
18.5 |
0.06
1.8 |
1.1
32 |
0.36 |
|
DS600SUM |
±0.3
±7.5 |
2.75
70 |
1.18
30 |
0.374
9.5 |
0.73
18.5 |
0.06
1.8 |
1.3
36 |
0.42 |
|
DS800SUM |
±0.4
±10 |
2.91
74 |
1.28
32.5 |
0.374
9.5 |
0.73
18.5 |
0.07
1.9 |
1.4
40 |
0.58 |
|
DS1000SUM |
±0.5
±12.5 |
3.54
90 |
1.38
35 |
0.374
9.5 |
0.73
18.5 |
0.08
2.3 |
1.8
50 |
0.78 |
|
General
AC "SUM" Specifications [Top
]
(See also
the statement
on LVDT specifications)
|
|
Supply
Requirements |
0.5
VAC to 7 VAC (RMS), 2 to 10 kHz sinusoidal |
|
Calibrated
Supply (Excitation) |
5
VAC (RMS) at 5 kHz sinusoidal, 30 mA |
|
Armature |
UNGUIDED |
|
Linearity
(% error of full scale, worst case) |
±0.5%* |
|
Phase
Shift |
Typically
10° at 5-VAC, 5-kHz excitation |
|
Output
Load (optimum) |
100
kΩ |
|
Temperature
Coefficient (Zero and Span) |
±0.01%
of full scale/°C (±0.005% of full scale/°F) |
|
Operating
Temperature Range |
-20°
C to +125° C (-4° F to +257° F) |
|
Operating
Pressure |
500
psi (sealed onto cable outer sleeve) |
|
Electrical
Termination |
6.5 ft. (2 m) shielded cable |
|
* ±0.25% and ±0.1% linearity are
optional on some models (contact
the factory for details). |
|