AC-Operated, Long-Stroke
Unguided Armature

 

"LU" LVDT Series (AC)

These high-performance transducers are the standard AC-EXCITED LONG-STROKE LVDT models with UNGUIDED ARMATURE.  They are ideal for harsh applications under conditions of high ambient temperature and/or vibration.

Each model requires separate signal conditioning, and will deliver its best performance when energized between 0.5 and 7 VAC (RMS) at 5 kHz, using a high-quality carrier amplifier.

Compact size allows use where physical space is limited.  All models are fitted with 2 meters (6.6 ft.) of shielded cable.  For hermetically sealed versions, see the AC "LUM" LVDT Series.

General Specifications are given below.

Go to LVDT SELECTION GUIDE


AC "LU" Series

Push rod diameter (shown as "D2") is 0.19 in. (4.75 mm) for all models;
armature diameter (inside transducer) is 0.24 in. (6 mm) for all models

LVDT
Model

Nom.
Linear
Range
(in. / mm)

Dimensions (in. / mm) Arma-
ture
Weight
(oz. / g)
Total
Weight
Nom.
Sensiti-
vity
(V/V
at f.s.)
Inward
Over-
travel
(in /
mm)*
"L" "X" "A" "D1" "ID"

DS1000LU

±0.5
±12.5

5
127
1.7
43
0.35
9
0.95
20.6
0.27
6.8
0.6
17
6 oz.
170 g
0.7 0.91
23

DS2000LU

±1
±
25

6
152
2.7
68
0.8
23
8 oz.
227 g
0.9 0.89
22.5

DS4000LU

±2
±50

10.6
270
3.2
81
1.3
37
11 oz.
316 g
1.5 0.62
15.8

DS6000LU

±3
±75

15
380
4.7
120
1.9
55
1 lb.
454 g
1.5 0.98
25

DS8000LU

±4
±100

16.75
425
5.2
132
2.5
71
1.25 lb.
568 g
3.2 0.73
18.6

DS12000LU

±6
±150

24.25
616
7.2
183
3.5
100
1.81 lb.
824 g
2.5 0.75
19

DS16000LU

±8
±
200

31.75
806
10.2
259
4.9
140
2.63 lb.
1193 g
1.5 1.05
26.6

* Outward overtravel is not applicable.

 

General AC "LU" Specifications  [Top ]

(See also the statement on LVDT specifications)

Supply Requirements

0.5 VAC to 7 VAC (RMS), 2 to 10 kHz sinusoidal

Calibrated Supply (Excitation)

5 VAC (RMS) at 5 kHz sinusoidal

Armature

UNGUIDED

Linearity (% error of full scale, worst case)

±0.5%*

Phase Shift

Typically 10° to 15° at 5-VAC, 5-kHz excitation

Output Load (optimum)

100 kΩ

Temperature Coefficient (Zero and Span)

±0.01% of full scale/°C (±0.005% of full scale/°F)

Operating Temperature Range

-51° C to +125° C (-60° F to +257° F)**

Electrical Termination

6.5 ft. (2 m) shielded cable

* ±0.25% and ±0.1% linearity are optional on some models (contact the factory for details).

** -51° C to +200° C (-60° F to +392° F) optional (contact the factory for details).

[Top ]
 
 

© 1996, 2002 Daytronic Corporation