These
high-performance transducers are the standard AC-EXCITED LONG-STROKE LVDT
models with UNGUIDED ARMATURE. They
are ideal for harsh applications under conditions of high ambient
temperature and/or vibration.
Each
model requires separate signal
conditioning, and will deliver its best performance when energized
between 0.5 and 7 VAC (RMS) at 5 kHz, using a high-quality carrier
amplifier.
Compact
size allows use where physical space is limited. All models are
fitted with 2 meters (6.6 ft.) of shielded cable. For hermetically
sealed versions, see the AC "LUM"
LVDT Series.
General Specifications are
given below.
Go
to LVDT SELECTION GUIDE
|
AC
"LU" Series
|
|

|
|
Push rod diameter (shown as "D2") is 0.19 in. (4.75
mm) for all models;
armature diameter (inside transducer) is
0.24 in. (6 mm) for all models |
|
LVDT
Model |
Nom.
Linear
Range
(in. / mm) |
Dimensions
(in. / mm) |
Arma-
ture
Weight
(oz. / g) |
Total
Weight |
Nom.
Sensiti-
vity
(V/V
at f.s.) |
Inward
Over-
travel
(in /
mm)* |
| "L" |
"X" |
"A" |
"D1" |
"ID" |
|
DS1000LU |
±0.5
±12.5 |
5
127 |
1.7
43 |
0.35
9 |
0.95
20.6 |
0.27
6.8 |
0.6
17 |
6
oz.
170 g |
0.7 |
0.91
23 |
|
DS2000LU |
±1
±25 |
6
152 |
2.7
68 |
0.8
23 |
8
oz.
227 g |
0.9 |
0.89
22.5 |
|
DS4000LU |
±2
±50 |
10.6
270 |
3.2
81 |
1.3
37 |
11
oz.
316 g |
1.5 |
0.62
15.8 |
|
DS6000LU |
±3
±75 |
15
380 |
4.7
120 |
1.9
55 |
1
lb.
454 g |
1.5 |
0.98
25 |
|
DS8000LU |
±4
±100 |
16.75
425 |
5.2
132 |
2.5
71 |
1.25
lb.
568 g |
3.2 |
0.73
18.6 |
|
DS12000LU |
±6
±150 |
24.25
616 |
7.2
183 |
3.5
100 |
1.81
lb.
824 g |
2.5 |
0.75
19 |
|
DS16000LU |
±8
±200 |
31.75
806 |
10.2
259 |
4.9
140 |
2.63
lb.
1193 g |
1.5 |
1.05
26.6 |
|
* Outward overtravel is not applicable. |
|
General
AC "LU" Specifications [Top
]
(See
also the statement
on LVDT specifications)
|
|
Supply
Requirements |
0.5
VAC to 7 VAC (RMS), 2 to 10 kHz sinusoidal |
|
Calibrated
Supply (Excitation) |
5
VAC (RMS) at 5 kHz sinusoidal |
|
Armature |
UNGUIDED |
|
Linearity
(% error of full scale, worst case) |
±0.5%* |
|
Phase
Shift |
Typically
10° to 15° at 5-VAC, 5-kHz excitation |
|
Output
Load (optimum) |
100
kΩ |
|
Temperature
Coefficient (Zero and Span) |
±0.01%
of full scale/°C (±0.005% of full scale/°F) |
|
Operating
Temperature Range |
-51°
C to +125° C (-60° F to +257° F)** |
|
Electrical
Termination |
6.5
ft. (2 m) shielded cable |
|
*
±0.25% and ±0.1% linearity are optional on some models (contact
the factory for details).
** -51° C to +200° C (-60° F to +392° F) optional (contact
the factory for details). |
|