General
AC "LEM" Specifications [Top
]
(See
also the statement
on LVDT specifications)
|
|
Supply
Requirements |
0.5
VAC to 7 VAC (RMS), 2 to 10 kHz sinusoidal |
|
Calibrated
Supply (Excitation) |
5
VAC (RMS) at 5 kHz sinusoidal |
|
Armature |
SPRING-EXTENDED |
|
Linearity
(% error of full scale, worst case) |
±0.5%* |
|
Phase
Shift |
Typically
10° to 15° at 5-VAC, 5-kHz excitation |
|
Output
Load (optimum) |
100
kΩ |
|
Temperature
Coefficient (Zero and Span) |
±0.01%
of full scale/°C (±0.005% of full scale/°F) |
|
Operating
Temperature Range (transducer)** |
-51°
C to +125° C (-60° F to +257° F) |
|
Operating
Pressure |
145
psi, maximum*** |
|
Electrical
Termination |
Connector
with 16 ft. (5 m) lead (options available) |
|
*
±0.25% and ±0.1% linearity are optional on some models (contact
the factory for details).
** Reduced to -40°
C to +90° C (-40° F to +194° F) by standard connector.
*** Ratings up to 3000 psi available with cable options
(contact the factory for
details). |