NOTE:
All of the AC "LE" Series LVDT's have retained their
"classic" Daytronic model numbers.
These
high-performance transducers are the standard AC-EXCITED LONG-STROKE LVDT
models with SPRING-EXTENDED ARMATURE. They
are ideal for harsh applications under conditions of high ambient
temperature and/or vibration.
Each
model requires separate signal
conditioning, and will deliver its best performance when energized
between 0.5 and 7 VAC (RMS) at 5 kHz, using a high-quality carrier
amplifier.
Compact
size allows use where physical space is limited. All models are
fitted with 2 meters (6.6 ft.) of shielded cable. For hermetically
sealed versions, see the AC "LEM"
LVDT Series.
General Specifications are
given below.
Go
to LVDT SELECTION GUIDE
|
AC
"LE" Series
|
|

|
|
LVDT
Model |
Nom.
Linear
Range
(in. / mm) |
Dimensions
(in. / mm) |
Nom.
Spring
Force
(max.) |
Body
Weight |
Nom.
Sensiti-
vity
(V/V
at f.s.) |
Overtravel
(in. / mm) |
| "L" |
"X" |
"A" |
"D1" |
Inward |
Outward |
|
DS1000A |
±0.5
±12.5 |
5.35
136 |
1.5
38 |
0.35
9 |
0.813
20.6 |
7
oz.
200 g |
6.5
oz.
184 g |
0.7 |
0.042
1.1 |
0.512
13 |
|
DS2000A |
±1
±25 |
6.35
161 |
2.5
63 |
9.9
oz.
280 g |
8
oz.
227 g |
0.9 |
0.12
2.5 |
0.4
10 |
|
DS4000A |
±2
±50 |
11
280 |
3.0
75 |
11.3
oz.
320 g |
14
oz.
398 g |
1.5 |
0.31
8 |
0.55
14 |
|
DS6000A |
±3
±75 |
15.35
390 |
4.5
114 |
1.4
lb.
650 g |
1.07
lb.
483 g |
1.5 |
0.59
15 |
0.59
15 |
|
General
AC "LE" Specifications [Top
]
(See
also the statement
on LVDT specifications)
|
|
Supply
Requirements |
0.5
VAC to 7 VAC (RMS), 2 to 10 kHz sinusoidal |
|
Calibrated
Supply (Excitation) |
5
VAC (RMS) at 5 kHz sinusoidal |
|
Armature |
SPRING-EXTENDED |
|
Linearity
(% error of full scale, worst case) |
±0.5%* |
|
Phase
Shift |
Typically
10° to 15° at
5-VAC, 5-kHz excitation |
|
Output
Load (optimum) |
100
kΩ |
|
Temperature
Coefficient (Zero and Span) |
±0.01%
of full scale/°C (±0.005% of full scale/°F) |
|
Operating
Temperature Range |
-51°
C to +125° C (-60° F to +257° F)** |
|
Electrical
Termination |
6.5
ft. (2 m) shielded cable |
|
*
±0.25% and ±0.1% linearity are optional on some models (contact
the factory for details).
** -51° C to
+200° C (-60° F to +392° F) optional (contact
the factory for details). |
|