AC-Operated, Long-Stroke
Spring-Extended Armature

 

"LE" LVDT Series (AC)

NOTE: All of the AC "LE" Series LVDT's have retained their "classic" Daytronic model numbers.

These high-performance transducers are the standard AC-EXCITED LONG-STROKE LVDT models with SPRING-EXTENDED ARMATURE.  They are ideal for harsh applications under conditions of high ambient temperature and/or vibration.

Each model requires separate signal conditioning, and will deliver its best performance when energized between 0.5 and 7 VAC (RMS) at 5 kHz, using a high-quality carrier amplifier.

Compact size allows use where physical space is limited.  All models are fitted with 2 meters (6.6 ft.) of shielded cable.  For hermetically sealed versions, see the AC "LEM" LVDT Series.

General Specifications are given below.

Go to LVDT SELECTION GUIDE


AC "LE" Series

LVDT
Model

Nom.
Linear
Range
(in. / mm)

Dimensions (in. / mm) Nom.
Spring
Force
(max.)
Body
Weight
Nom.
Sensiti-
vity
(V/V
at f.s.)
Overtravel
(in. / mm)
"L" "X" "A" "D1" Inward Outward

DS1000A

±0.5
±
12.5

5.35
136
1.5
38
0.35
9
0.813
20.6
7 oz.
200 g
6.5 oz.
184 g
0.7 0.042
1.1
0.512
13

DS2000A

±1
±
25

6.35
161
2.5
63
9.9 oz.
280 g
8 oz.
227 g
0.9 0.12
2.5
0.4
10

DS4000A

±2
±
50

11
280
3.0
75
11.3 oz.
320 g
14 oz.
398 g
1.5 0.31
8
0.55
14

DS6000A

±3
±75
15.35
390
4.5
114
1.4 lb.
650 g
1.07 lb.
483 g
1.5 0.59
15
0.59
15

 

General AC "LE" Specifications  [Top ]

(See also the statement on LVDT specifications)

Supply Requirements

0.5 VAC to 7 VAC (RMS), 2 to 10 kHz sinusoidal

Calibrated Supply (Excitation)

5 VAC (RMS) at 5 kHz sinusoidal

Armature

SPRING-EXTENDED

Linearity (% error of full scale, worst case)

±0.5%*

Phase Shift

Typically 10° to 15° at 5-VAC, 5-kHz excitation

Output Load (optimum)

100 kΩ

Temperature Coefficient (Zero and Span)

±0.01% of full scale/°C (±0.005% of full scale/°F)

Operating Temperature Range

-51° C to +125° C (-60° F to +257° F)**

Electrical Termination

6.5 ft. (2 m) shielded cable

* ±0.25% and ±0.1% linearity are optional on some models (contact the factory for details).

**
-51° C to +200° C (-60° F to +392° F) optional (contact the factory for details).

[Top ]
 
 