These
high-performance transducers are the standard AC-EXCITED LONG-STROKE LVDT
models with CAPTIVE ARMATURE. They
are ideal for harsh applications under conditions of high ambient
temperature and/or vibration.
Each
model requires separate signal
conditioning, and will deliver its best performance when energized
between 0.5 and 7 VAC (RMS) at 5 kHz, using a high-quality carrier
amplifier.
Compact
size allows use where physical space is limited. All models are
fitted with 2 meters (6.6 ft.) of shielded cable. For hermetically
sealed versions, see the AC "LCM"
LVDT Series.
General Specifications are
given below.
Go
to LVDT SELECTION GUIDE
|
AC
"LC" Series
|
|

|
|
REAR
MOUNT: M5 x 0.8 female, 0.43 in. (11 mm) deep
FRONT MOUNT: M5 x 0.8, 0.6 in. (15 mm) long |
|
LVDT
Model |
Nom.
Linear
Range
(in. / mm) |
Dimensions
(in. / mm) |
Body
Weight |
Nom.
Sensiti-
vity
(V/V
at f.s.) |
Overtravel
(in. / mm) |
| "L" |
"X" |
"A" |
"D1" |
Inward |
Outward |
|
DS1000LC |
±0.5
±12.5 |
5.98
152 |
1.5
38 |
0.95
24 |
0.813
20.6 |
10
oz.
284 g |
0.7 |
0.51
13 |
0.42
10.6 |
|
DS2000LC |
±1
±25 |
7.01
178 |
2.5
63 |
12
oz.
340 g |
0.9 |
0.51
13 |
0.39
10 |
|
DS4000LC |
±2
±50 |
11.61
295 |
3.0
75 |
1.1
lb.
511 g |
1.5 |
0.39
10 |
0.55
14 |
|
DS6000LC |
±3
±75 |
15.98
406 |
4.5
114 |
1.44
lb.
653 g |
1.5 |
0.94
24 |
0.59
15 |
| DS8000LC |
±4
±100 |
17.8
452 |
5.0
127 |
1.57
lb.
710 g |
3.2 |
0.31
8 |
0.55
14 |
| DS12000LC |
±6
±150 |
25.31
643 |
7.0
178 |
2.25
lb.
1022 g |
2.5 |
0.48
12.3 |
0.68
17.2 |
| DS16000LC |
±8
±200 |
32.80
833 |
10.0
254 |
3.13
lb.
1420 g |
1.5 |
0.87
22 |
1
25 |
| DS20000LC |
±10
±250 |
40.55
1030 |
12.0
305 |
3.5
lb.
1590 g |
2 |
1.34
34 |
1.38
35 |
| DS30000LC |
±15
±375 |
56.5
1435 |
16.0
406 |
4.7
lb.
2130 g |
3.2 |
0.5
12.5 |
0.5
12.5 |
| DS37000LC |
±18.5
±470 |
67.01
1702 |
20.0
508 |
5.57
lb.
2528 g |
3.6 |
0.2
5 |
1.3
33 |
|
General
AC "LC" Specifications [Top
]
(See
also the statement
on LVDT specifications)
|
|
Supply
Requirements |
0.5
VAC to 7 VAC (RMS), 2 to 10 kHz sinusoidal |
|
Calibrated
Supply (Excitation) |
5
VAC (RMS) at 5 kHz sinusoidal |
|
Armature |
CAPTIVE
(GUIDED) |
|
Linearity
(% error of full scale, worst case) |
±0.5%* |
|
Phase
Shift |
Typically
10° to 15° at 5-VAC, 5-kHz excitation |
|
Output
Load (optimum) |
100
kΩ |
|
Temperature
Coefficient (Zero and Span) |
±0.01%
of full scale/°C (±0.005% of full scale/°F) |
|
Operating
Temperature Range |
-51°
C to +125° C (-60° F to +257° F)** |
|
Electrical
Termination |
6.5
ft. (2 m) shielded cable |
|
*
±0.25% and ±0.1% linearity are optional on some models (contact
the factory for details).
** -51° C to +200° C (-60° F to +392° F) optional (contact
the factory for details). |
|