Go to Summary of Instrument Capabilities

Go to Instrument Models for Specific Transducers

Versatile Instrument Intelligence Coupled with Outstanding Measurement Accuracy

The ultimate quality of any electronic measurement depends on how the "raw" measurement signal is handled.  Based on over 47 years' experience in the field of ANALOG SIGNAL CONDITIONING, Daytronic instruments perform all required conditioning tasks—including per-channel analog and digital filtering, A/D conversion, scaling, and linearizing—to ensure true, noise-free, drift-free measurement results, even in the face of substantial dynamic content.

Each instrument's conditioning characteristics are optimized for a particular type of transducer input (see Instrument Models for Specific Transducers, below). 

These "intelligent" instruments do much more than just signal conditioning.  Except for the 5D Series of simple conditioning "blocks," each instrument series is capable of evaluating acquired data and initiating necessary actions for REAL-TIME PROCESS CONTROL.

The more sophisticated 4000 Series instruments can also perform a wide range of SIGNAL PROCESSING functions, including cross-channel calculations for ON-LINE SPC.  In addition, they can be easily programmed by the operator to automatically execute a sequence of standard functions on detection of a given process condition or event.

2000 Series, 3KPlus Sereis, 3500 Series, and 4000 Series instruments can serve as high-speed COMPUTER OR PLC "FRONT ENDS"—in both single-node and multinode (network) environments.  As such, they are completely "STAND-ALONE."  Each instrument is independently responsible for all of its own local data acquisition and control tasks, providing the supervisory host device with finished measurement answers whenever this data is requested.

Go to
Summary of Daytronic

System Capabilities


Summary of Instrument Capabilities  [Top ]

 

Signal Conditioning and Data Display

Real-Time Signal Processing and Process Control

Data Communications

Programmability, Operability, and Security

Table Legend:

S

Standard for ALL models

SS

Standard for SOME models

O

Optional for ALL models

OS

Optional for SOME models

Signal Conditioning and Data Display  [Back ]

 

5D
Series

2000
Series
3000
Series
3KPlus
Series
3500
Series
4000
Series

Analog Signal Conditioning
with Multipole Low-Pass Active Filtering and Regulated, Remotely Sensed Excitation

S

  S S S S

Concurrent Slope A/D Conversion

 

S1        

Microprocessor-Based 16-Bit A/D Conversion

 

    S S S

TRANSDUCER INPUTS Accommodated
(see Instrument Models for Specific Transducers):

THERMOCOUPLE

 

     

PLATINUM RTD (100 Ω)

 

       

LVDT & Variable Reluctance

 

SHAFT ENCODER (Quadrature)

 

       

FREQUENCY (Pulse, RPM, etc.)

 

DC VOLTAGE

 

DC CURRENT

 

     

AC VOLTAGE (RMS)

 

     

AC CURRENT (RMS)

 

       

DC-EXCITED STRAIN GAGE

AC-EXCITED STRAIN GAGE

 

Multiple Transducer Inputs

 

SS       SS

Selectable Analog Filtering

S

  SS S SS  

Selectable Digital Filtering

 

S   S S S

Internal Custom Linearization

 

OS     S S

Front-Panel Digital Indication

 

S SS S S S

Front-Panel Bargraph Data and Limit-Value Display

 

        S

Real-Time Signal Processing and Process Control  [Back ]

 

5D
Series

2000
Series
3000
Series
3KPlus
Series
3500
Series
4000
Series

Continuous Limit Monitoring 
with Isolated Logic Control Outputs

 

O SS S S S

Front-Panel Annunciation of Limit Status

 

O SS S S S

Programmable Limit Hysteresis

 

O   S S  

"Live" Analog Output (± 0 to 5 VDC)

S

  S2 S S3  

"Live" Analog Output (± 0 to 10 VDC)

 

O   S   S3

"Live" Analog Output (CURRENT)

 

O OS S    

Real-Time Analog Peak Capture

 

  OS   SS SS

Digital Peak Capture and Hold ("MAX/MIN")

 

S   S SS S

Digital Track and Hold

 

    S S S

Real-Time Math Processing (including Constants)

 

OS       S

Auto-Zero / Auto-Tare Capability

 

S   S S S

Counter or Counter/Timer Functions

 

SS       S

Real-Time SPC Capability

 

        SS

Programmable Logic I/O

 

        S

Internal Electromechanical and/or Solid-State Relays

 

O OS S    

Automatic Bit-Controlled Command Execution

 

        S

Data Communications  [Back ]

 

5D
Series

2000
Series
3000
Series
3KPlus
Series
3500
Series
4000
Series

RS232 Data Communications

 

O   S S S

RS485 (Network) Data Communications

 

O     S SS
OS

RS422 and IEEE-488 Data Communications

 

      O O

Parallel BCD Data Communications

 

O        

Formattable Serial-ASCII Data Transmissions

 

O     S S

"Time-Coherent" Serial-ASCII Data Transmissions

 

        S

Programmability, Operability, and Security  [Back ]

 

5D
Series

2000
Series
3000
Series
3KPlus
Series
3500
Series
4000
Series

Front-Panel Setup and Run-Time Operation

 

S S S S S

Setup via Keyboard and/or External Computer/Terminal

 

O   O O O

Setup via Configuration Software

S

O   O   OS

Run-Time Operation via Keyboard and/or External Computer/Terminal

 

    O O O

Configuration Security

 

S   S S S

User-Programmable Front-Panel Buttons and Annunciators

 

        S

DC-Powered Operation

S

O O S   OS

Software for Network Management, Data Display and Communications, and/or Other Utilities

 

O     O O

1

Includes ISOLATED SELECTABLE EXCITATION.  [Back ]

2

Multiple frequency-dependent outputs available for most models.  GALVANIC ISOLATED OUTPUTS optional for some 3000 models.  [Back ]

3

Voltage output is scalable by the user.  [Back ]

 


Instrument Models for Specific Transducers
[Top ]

NOTE: Where the instrument model accepts multiple inputs of the given transducer type, the number of inputs is indicated in parentheses following the model number

 

Thermocouples

100-Ω Platinum RTD's

LVDT's & Variable Reluctance Transducers

Shaft Encoders ("A," "B," and "Z" Signals)

Frequency Sources

DC Voltage Sources

AC (RMS) Voltage Sources

DC Current Sources (4-20 mA)

AC (RMS) Current Sources

DC-Excited Strain Gage Transducers

AC-Excited Strain Gage Transducers

Temperature

    Thermocouples  [Back ]

 

5D
Series

2000
Series
3000
Series
3KPlus
Series
3500
Series
4000
Series

Type B

          4010 (4)

Type E

  2113-1
(°C)
2113-2
(°F)
      4010 (4)

Type J

  2110-1
(°C)
2110-2
(°F)
      4010 (4)

Type K

  2111-1
(°C)
2111-2
(°F)
      4010 (4)

Type N

  2114-1
(°C)
2114-2
(°F)
       

Type R

  2116-1
(°C)
2116-2
(°F)
      4010 (4)

Type S

  2115-1
(°C)
2115-2
(°F)
      4010 (4)

Type T

  2112-1
(°C)
2112-2
(°F)
      4010 (4)
    100-Ω Platinum RTD's  [Back ]

 

5D
Series

2000
Series
3000
Series
3KPlus
Series
3500
Series
4000
Series

DIN 
(α = 0.00385)

  2118-1
(°C)
2118-2
(°F)
       

ANSI 
(α = 0.003925)

  2119-1
(°C)
2119-2
(°F)
       

Displacement

    LVDT's and Variable Reluctance Transducers  [Back ]

 

5D
Series

2000
Series
3000
Series
3KPlus
Series
3500
Series
4000
Series

 

5D30   3130
3230
3330
3KPlus-30 3530 4030
4032
(2)
4K/SPC-30
4K/SPC-32 (2)
    Shaft Encoders ("A," "B," and "Z" Signals)  [Back ]

 

5D
Series

2000
Series
3000
Series
3KPlus
Series
3500
Series
4000
Series

 

  2135        

Frequency

    Frequency Sources*  [Back ]

 

5D
Series

2000
Series
3000
Series
3KPlus
Series
3500
Series
4000
Series

 

5D40 2140 (2)
2140R (2)
3140A
3240A
3340A
3KPLUS-40 3540 4040
4K/HP**

* E.g., AC waveforms, tachometer pickups, turbine flowmeters, transistor or logic-circuit drivers, "zero-velocity" sensors, etc.

** The Model 4K/HP Horsepower Instrument has both a FREQUENCY input channel (for measurement of RPM) and an AC STRAIN GAGE input channel (for measurement of TORQUE).

Voltage / Current

    Voltage Sources  [Back ]

 

5D
Series

2000
Series
3000
Series
3KPlus
Series
3500
Series
4000
Series

DC Voltage

5D64 2160
2162*
2162X*
3163
3263
3363
3KPlus-64 3560 4060
4062
(2)
4K/SPC-60
4K/SPC-62 (2)

AC (RMS)
Voltage

  2168       4060
4K/SPC-60

* The Models 2162 and 2162X are dedicated primarily to the measurement of 4-20 mA PROCESS SIGNALS, but may also be used to produce scalable VOLTAGE readout from strain gages, or in potentiometer follower applications.

    Current Sources  [Back ]

 

5D
Series

2000
Series
3000
Series