3a Results:



Single Channel, Signal Conditioning for Measuring Force, Pressure, Weight or Torque

The products that fit these requirements are:
  • Model 3170- A simple, high-quality signal conditioner for a DC Strain Gage input. Being in Form 1 of the 3000 Instrument Series, the Model 3170 features selectable low-pass active filtering, built-in regulated excitation and internal reference calibration standards, and provides the most accurate drift-free analog outputs possible.

  • Model 3178- A simple, high-quality signal conditioner for an AC Strain Gage input. Being in Form 1 of the 3000 Instrument Series, the Model 3178 is intended for applications involving transformer coupling to the transducer bridge (as with rotary-transformer torque sensors). This unit is designed to reject extraneous voltages that can cause erros in DC systems, particularly when there is a need to "blow up" a portion of the transducer range.


[ Start Over ] - [ Previous ]



Single Channel, Signal Conditioning with Display for Measuring Force, Pressure, Weight or Torque

The products that fit these requirements are:
  • Model 3270- A high-quality signal conditioner for a DC Strain Gage input. Being in Form 2 of the 3000 Instrument Series, the Model 3270 features a rock-solid LED display which provides selectable decimal-point locations, optional dummy zero, and an assortment of engineering unit legends, in addition to the other field-proven charateristics of the 3000 Series.

  • Model 3278- A simple, high-quality signal conditioner for an AC Strain Gage input. Being in Form 1 of the 3000 Instrument Series, the Model 3278 is intended for applications involving transformer coupling to the transducer bridge (as with rotary-transformer torque sensors). This unit is designed to reject extraneous voltages that can cause erros in DC systems, particularly when there is a need to "blow up" a portion of the transducer range.


[ Start Over ] - [ Previous ]



Single Channel, Signal Conditioning, Display and Limits for Measuring Force, Pressure, Weight or Torque

The products that fit these requirements are:
  • Model 3370- A high-quality signal conditioner for a DC Strain Gage input. Being in Form 3 of the 3000 Instrument Series, the Model 3370 provides two control setpoints, along with a rock-solid LED display. The limits are indepentently adjustable over the full +/- range via the front panel, and indicated by front panel LEDs. The unit also provides selectable decimal-point locations and optional dummy zero, in addition to the other field-proven charateristics of the 3000 Series.

  • Model 3378- A simple, high-quality signal conditioner for an AC Strain Gage input. Being in Form 1 of the 3000 Instrument Series, the Model 3378 is intended for applications involving transformer coupling to the transducer bridge (as with rotary-transformer torque sensors). This unit is designed to reject extraneous voltages that can cause erros in DC systems, particularly when there is a need to "blow up" a portion of the transducer range.

  • Model TM3- The Model TM3 is a specially modified Model 3370 with peak option, so that it becomes a simple, economical benchtop unit for automatic capture, display, and evaluation of the true "real-time" maximum value experienced by a single analog torque signal.


[ Start Over ] - [ Previous ]



Single Channel, Signal Conditioning, Display, Limits and RS-232/485 Connectivity for Measuring Force, Pressure, Weight or Torque

The products that fit these requirements are:
  • Model 3570- A step up from the 3000 Instrument Series, the Model 3570 is the DC Strain Gage conditioner of the 3500 Instrument Series. This series offers the same high-quality signal conditioning features, but comes standard with 3 user-defined limit zones, 5-digit LCD display, RS-232/485 communication interface, and supplies amplitude-regulated 3280-Hz AC excitation.

  • Model 3578- A step up from the 3000 Instrument Series, the Model 3578 is the AC Strain Gage conditioner of the 3500 Instrument Series, the Model 3578 is intended for applications involving transformer coupling to the transducer bridge (as with rotary-transformer torque sensors). This unit is designed to reject extraneous voltages that can cause erros in DC systems, particularly when there is a need to "blow up" a portion of the transducer range.


[ Start Over ] - [ Previous ]




Single Channel, Signal Conditioning with Programmable Control for Measuring Force, Pressure, Weight or Torque

The products that fit these requirements are:
  • Model 4077- A signal conditioning instrument with system-level functionality, the Model 4077 accepts a DC Strain Gage input. The 4000 Instrument Series offers simultaneous digital and analog indication, limit monitoring and local real-time control, high-speed "single-" or "multi-node" communication, real-time calculates, automatic command execution, and front panel or remote setup, with additional configuration security.

  • Model 4078- A signal conditioning instrument with system-level functionality, the Model 4078 accepts an AC Strain Gage input. The Model 4078 is similar to the 4077, but is intended for applications involving transformer coupling to the transducer bridge (as with rotary-transformer torque sensors). This unit is designed to reject extraneous voltages that can cause erros in DC systems, particularly when there is a need to "blow up" a portion of the transducer range.