Model 10A68-2
Dual AC RMS Conditioner
This conditioner accurately measures the true RMS amplitude of one or two independent external analog AC signals, mixed as desired, from a wide range of voltage or current sources- including engineering parameters conditioned by other Daytronic cards. Since the 10A68-2 does not provide excitation, the analog source must supply its own power supply, if required (as is the case with many accelerometers, when used to measure the noise level or vibration factor of a dynamic process). The card is particularly useful in evaluating the efficiency of AC electrical power systems.
The 10A68-2 mates with a special connector board that has a separate screw-terminal block for each input channel. In System 10, "absolute" calibration may be used for a 10A68-2 channel if the parameter being measured is voltage itself. "Two-point" ("deadweight") calibration should be used if the voltage or current input signal is an analog of some other parameter that has at least two independently and accurately known calibration values. In the SPS6000 System, both "calculated" and "two-point" calibration are available.The table below gives for each allowable full-scale input range the normal-mode input impedance (Zi), maximum normal-mode input voltage or current with no instrument damage (Vmax or Imax), and bandwidth flat to 0.1%, 1%, and 3 dB, respectively. Specifications:
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||