Model 10A17-2
Dual High-Voltage Isolation RTD Conditioner


Input Type Description SPS6000 SPS8000 System 10
Temperature Dual High-Voltage Isolation RTD
X-X
X-X
X*X


Designed for RTD-based temperature measurements requiring high input isolation, this precision conditioner is particularly useful in the utilities industry. It is identical to the Model 10A16-4C, except that
  • it accepts two independent platinum RTD signals (rather than four), and may only be used in System 10
  • its inputs are transformer-isolated, so that sensor-to-chassis and/or sensor-to-sensor common-mode voltages as high as 1500 V-DC can be accommodated without damaging the instrument or perceptibly affecting measurement accuracy
Specifications:
  • RTD Types: Platinum; DIN (European) standard with "ice-point" resistance of 50, 100, or 200 ohm, or American standard with "ice-point" resistance of 100 ohm
  • Range and Resolution: See Table below; automatically selected- on an individual channel basis- when the channel is configured
  • Linearization: Internal digital linearization; maximum error: ±0.1° C (±0.2° F)
  • Excitation (per channel): Nominal 5 V-DC; 1 mA, maximum
  • Amplifier (per channel):
      Common-Mode Range: ±1500 V operating and without instrument damage
      Common-Mode Rejection Ratio: DC: -150 dB; at 60 Hz: -160 dB; at 1 kHz and 3 kHz: infinite
      Leadwire Resistance Rejection (4-wire only): 0.004% per ohm
      Offset: Initial: ±0.01% of full scale; vs. Temperature: ±10 ppm/°C; vs. Time: ±10 ppm/month
      Gain Accuracy: ±0.02% of full scale
      Gain Stability: vs. Temperature: ±50 ppm/°C; vs. Time: ±50 ppm/month
  • Filter (per channel): 3-pole modified Butterworth; 3 dB down at 2 Hz; 60 dB down at 30 Hz
      Step-Response Settling Time (Full-Scale Output):
      To 1% of final value: 260 msec
      To 0.1% of final value: 500 msec
      To 0.02% of final value: 600 msec
  • Total System Accuracy (typical, including Model 10A17-2 and system data collection and processing): see Table below
  • Auxiliary Outputs: Filtered outputs available on wire-wrap pins


RTD Ranges for the Models 10A17-2

Platinum
RTD
Standard


Resistance

Range
Display
Resolution3

Typical
System
Accuracy4

Max.
Expected
Error4

DIN1
DIN1
DIN1
DIN1
50 ohm
50 ohm
50 ohm
50 ohm
-150°C to +600°C
-150°C to +600°C
-238°F to +1112°F
-238°F to +1112°F
1.0°C
0.1°C
1.0°F
0.2°F
±1°C
±0.2°C
±1°F
±0.3°F
±1.3°C
±0.4°C
±1.5°F
±0.6°F
DIN1
DIN1
DIN1
DIN1
100 ohm
100 ohm
100 ohm
100 ohm
-150°C to +600°C
-150°C to +600°C
-238°F to +1112°F
-238°F to +1112°F
1.0°C
0.1°C
1.0°F
0.2°F
±1°C
±0.2°C
±1°F
±0.3°F
±1.3°C
±0.4°C
±1.5°F
±0.6°F
DIN1
DIN1
DIN1
DIN1
200 ohm
200 ohm
200 ohm
200 ohm
-150°C to +600°C
-150°C to +600°C
-238°F to +1112°F
-238°F to +1112°F
1.0°C
0.1°C
1.0°F
0.2°F
±1°C
±0.2°C
±1°F
±0.3°F
±1.3°C
±0.4°C
±1.5°F
±0.6°F
American2
American2
100 ohm
100 ohm
-150°C to +600°C
-238°F to +1112°F
0.1°C
0.2°F
±0.2°C
±0.3°F
±0.4°C
±0.6°F

1 alpha = 0.00385 (Back to Table)
2 alpha = 0.00392 (Back to Table)
3 Note that a specially modified version of the 10A17-2 yields resolution of 0.01° C (0.02° F) when used with System 10 "custom linearization." (Back to Table)
4 Including ± one count of least significant digit displayed (i.e., ± 1, 0.2, or 0.1) (Back to Table)