Using
Daytronic's 5D
Series Signal Conditioner Modules, each DataNode16 is a
software-configurable multichannel system for bringing low-level sensor signals to multiple devices—including
PC's, PLC's, local SCADA networks, and even web browser interfaces.
The
low-noise rackmount chassis hosts up to 16 mixed 5D conditioners to create a highly accurate and
stable front-end device for the acquisition, recording, and transmission
of data—and one that performs at remarkably high speed.
DataNode16's
internal processor scans, scales, and digitizes 5D measurements at 16-bit
resolution and a rate of 64 kHz (4 kHz per channel).
Its fully open communications
platform provides fast, seamless transfer of finished-answer data
over a single cable, using the standard Modbus addressable
protocol. It's ideal for real-time data exchange with OPC client
applications. And it can receive simple ASCII mnemonic commands from any
of its host devices for purposes of interrogation, on-the-fly
reconfiguration, and local control.
DataNode16
also features
 |
Up
to 64 internal
cross-channel calculations, including MAX, MIN, and AVERAGE |
 |
Continuous
HI/LO limit monitoring of selected data channels and
calculations |
 |
Two
independent history recorders, with programmable channel
lists and store conditions, operating in either circular (FIFO) or
fill-and-stop mode; store conditions include time intervals, input
triggers, and limit violation |
|
|
| DataNode16
General Specifications |
|
Dimensions |
Fits
3U 19-inch rack
Height: 3.479 in.
Width: Front: 18.944 in.; Rear: 17.320 in.
Depth: 10.34 in. |
|
Operating
Temperature Range |
-10° C to 70° C
(14° F to 158° F) |
|
Operating
Relative Humidity |
5%
to 95%, noncondensing |
|
Power
Requirements |
85
to 264 VAC RMS; 1.4 A |
|
Power
Output |
Isolated
24 VDC, 100 mA (via front-panel terminal, for powering digital
triggers; see diagram, above) |
|
Analog
Inputs |
Individual
sensor inputs of up to 16 standard 5D
Series Signal Conditioner Modules installed in the
DataNode16
NOTE: "V-" and "S-version"
models may not be used. |
|
Processor
Speed |
133
MHz |
|
A/D
Conversion |
16-bit |
|
Scan
Rate |
64
kHz; 4 kHz per channel |
|
Memory |
64MB
SDRAM; 32MB Flash Disc-on-Chip |
|
Analog
Outputs (Isolated) |
One
per installed conditioner module; filtered ± 0 to 5
VDC (this is module "Output A"; see 5D
Series General Specifications) |
|
Digital
Inputs |
Four
isolated logic-level triggers for history recording, via front-panel
terminals (see diagram, above); active low |
|
Isolation |
500
VAC (10 mA cutoff, 1 minute) |
|
Voltage
Range |
0
to +24 VDC |
|
Overvoltage
Protection |
Up
to ±48 VDC (36 VAC RMS) |
|
Operating
Frequency |
100
kHz minimum |
|
Communications |
Rear-panel
I/O ports for RS232 and RS485 Modbus |
|
Front-Panel
Indication |
Power,
Communications (Modbus activity) |
|
Individual
Module Status Indication |
Green/Yellow/Red;
indicates conditioner module input and communications status (see 5D
Series General Specifications for details) |
|