GENERAL PAGE
|
|
Back to
4000 Series
MODELS
|
|
Summary
of
4000
Series "Standard Configurations"
|
|
PLEASE NOTE: Initial setup parameters which can easily be defined
by the operator via the instrument's front-panel buttons are not
given here—e.g., channel on DISPLAY, channel DIGITAL FILTERING
constants, channel CALIBRATION VALUES (including LINEARIZATION POINTS),
channel LIMIT VALUES, "NODE" NUMBER (for "N" Option
instruments only), BAUD RATE, NUMBER OF DATA BITS, NUMBER OF STOP BITS,
and PARITY.
Also,
details of internal LIMIT LOGIC, LOGIC SOURCING, "CALCULATES,"
and "EXECUTES" employed for "standard configuration"
functions are not given here (they may be found in the respective 4000
Series Instrument Instruction Manuals).
|
|
All
Models
[Back
] |
|
MISCELLANEOUS
SETUP PARAMETERS |
| DLY
(Intertransmission
Delay) |
0 |
| CMT
(Command
Terminator) |
[0D] |
| OPT
(Output
Terminator) |
[00,0D] |
| EOT
(End-of-Transmission
Terminator) |
[00,0D] |
| SCN
(Scan Range) |
1,19* |
|
TER
(Scan Terminator
Channel) |
19* |
| EDT
("Editor"—Front-Panel
Setup Enabled?) |
Y |
| BAR
(Bargraph Mode) |
DIS |
| BEP
(Bargraph Endpoint Mode) |
LEP |
| FLA
(Trigger Bit for Display
"Flashing") |
1000 |
| CPC
(Characters per Channel of
Output) |
9 |
| CLM
(Number of Columns of
Output) |
1 |
| XBG1
(Execute Base Group 1) |
1 |
| XBG2
(Execute Base Group 2) |
2 |
|
|
*
For the Model 4K/HP (only), the initial SCN value is
"1,24" and the initial TER value is "24." |
|
Model
4010
Four-Channel Thermocouple Instrument
[Back
] |
|
SCANNED
DATA CHANNELS |
| 1-4 |
"Live"
Temperature Inputs |
| 5 |
"Live"
Cold-Junction Temperature |
| 6-12 |
"Calculate"
channels for internal processing |
| 12 |
"Live"
Average of Channels 1 through 4 |
| 13-18 |
Not
used |
| 19 |
ANALOG
OUTPUT (derived from Channel 12) |
|
|
CHANNEL
RANGES AND SCALING |
Channels
1-4 are each initially set for operation with a Type J Thermocouple
and for measurement in degrees F; the ±10 VDC Analog Output
Channel (No. 19) is initially scaled for 1 mV of output per 1 degree
of temperature (°F or °C) for the current reading of Channel 12 |
|
LOGIC
I/O PORTS |
| 0 |
Not
used |
| 1-4 |
NONLATCHING
OUTPUTS: Corresponding "Live" Temperature Input
Channel (1-4) is "NOT OK" (i.e., either less
than "LOL" limit value or greater than "HIL"
limit value) |
| 5 |
NONLATCHING
OUTPUT: "Live" Average Channel (12) is "NOT
OK" (i.e., either less than "LOL"
limit value or greater than "HIL" limit value) |
| 6-7 |
Not
used |
|
|
PROGRAMMABLE
FRONT-PANEL BUTTONS |
| 1-4 |
TEMP1,
TEMP2, TEMP3, and TEMP4: Displays
corresponding "Live" Temperature Input channel (1-4)
and lights the respective indicator |
| 5 |
AVG:
Displays "Live" Average Channel (12) and lights the
"AVG" indicator |
|
|
PROGRAMMABLE
FRONT-PANEL INDICATORS |
| 1 |
TEMP1 |
(above
Button 1) |
| 2 |
TEMP2 |
(above
Button 2) |
| 3 |
TEMP3 |
(above
Button 3) |
| 4 |
TEMP4 |
(above
Button 4) |
| 5 |
AVG |
(above
Button 5) |
| 6 |
°C |
(bottom
unit legend) |
| 7 |
°F |
(middle
unit legend)—INITIALLY LIT |
| 8 |
ON
LINE |
(top
unit legend) |
|
|
"LOGO"
FOR OPTIONAL 10P80D/10P25D
DISPLAY |
4010
STANDARD |
|
MISCELLANEOUS
SETUP PARAMETERS |
See
All Models |
|
Model
4030
Single-Channel AC LVDT Instrument
[Back
] |
|
SCANNED
DATA CHANNELS |
| 1 |
"Live"
LVDT Input |
| 2-3 |
Not
used |
| 4 |
"Calculate"
channel for internal processing |
| 5 |
"Live"
Input with Tare |
| 6 |
MAXIMUM
value of Channel 5 since last reset |
| 7 |
MINIMUM
value of Channel 5 since last reset |
| 8 |
"MAX
MINUS MIN" value of Channel 5 since last reset
(= net difference between Channel 6 and Channel 7) |
| 9-13 |
Not
used |
| 14-16 |
"Calculate"
channels for internal processing |
| 17-18 |
Not
used |
| 19 |
ANALOG
OUTPUT (derived from Channel 5) |
|
|
CHANNEL
RANGES AND SCALING |
The
sensitivity range for Channel 1 is automatically adjusted to accommodate
the full-scale input range; the ±10 VDC Analog Output
Channel (No. 19) is initially scaled for 1 mV of output per 0.001
unit of length for the current reading of Channel 5 |
|
LOGIC
I/O PORTS |
| 0 |
NONLATCHING
OUTPUT: "Live" Input with Tare (Channel 5) is in "BELOW
BARGRAPH" limit zone |
| 1 |
NONLATCHING
OUTPUT: "Live" Input with Tare (Channel 5) is in LOWER
"DANGER" limit zone |
| 2 |
NONLATCHING
OUTPUT: "Live" Input with Tare (Channel 5) is in LOWER
"CAUTION" limit zone |
| 3 |
NONLATCHING
OUTPUT: "Live" Input with Tare (Channel 5) is in SAFETY
(OK) limit zone |
| 4 |
NONLATCHING
OUTPUT: "Live" Input with Tare (Channel 5) is in UPPER
"CAUTION" limit zone |
| 5 |
NONLATCHING
OUTPUT: "Live" Input with Tare (Channel 5) is in UPPER
"DANGER" limit zone |
| 6 |
NONLATCHING
OUTPUT: "Live" Input with Tare (Channel 5) is in "ABOVE
BARGRAPH" limit zone |
| 7 |
Not
used |
|
|
PROGRAMMABLE
FRONT-PANEL BUTTONS |
| 1 |
"LIVE
DISPLAY": Displays
"Live" Input with Tare (Channel 5) and lights the
"F1" indicator |
| 2 |
Not
used |
| 3 |
"TARE":
Zeroes Channel 5 so that subsequent readings of Channel 5 will
represent the value of Channel 1 ("Live" Input) minus
the existing value of Channel 1 (now stored as a constant
"tare" offset) |
| 4 |
"MAX/MIN/MAX-MIN
STEP":
If
Channel 5 is currently on display, displays Channel 6
("MAX" of Channel 5) and lights the "F3"
indicator
If
Channel 6 is currently on display, displays Channel 7
("MIN" of Channel 5) and lights the "F4"
indicator
If
Channel 7 is currently on display, displays Channel 8 ("MAX
– MIN" of Channel 5) and lights the "F5"
indicator
If
Channel 8 is currently on display, displays Channel 5
("Live" Input with Tare) and lights the "F2"
indicator
|
| 5 |
"MAX/MIN
RESET": Resets the "MAX-" and
"MIN-"measuring functions of Channels 6 and 7,
respectively |
|
|
PROGRAMMABLE
FRONT-PANEL INDICATORS |
| 1 |
F1 |
(above
Button 1) |
| 2 |
F2 |
(above
Button 2)—NOT USED |
| 3 |
F3 |
(above
Button 3) |
| 4 |
F4 |
(above
Button 4) |
| 5 |
F5 |
(above
Button 5) |
| 6 |
milli/in |
(bottom
unit legend) |
| 7 |
inches |
(middle
unit legend)—INITIALLY LIT |
| 8 |
mm |
(top
unit legend) |
|
|
"LOGO"
FOR OPTIONAL 10P80D/10P25D
DISPLAY |
4030
STANDARD |
|
MISCELLANEOUS
SETUP PARAMETERS |
See
All Models |
|
Model
4032
Two-Channel AC LVDT Instrument
[Back
] |
|
SCANNED
DATA CHANNELS |
| 1 |
"Live"
LVDT Input A |
| 2 |
"Live"
LVDT Input B |
| 3 |
Not
used |
| 4 |
"Calculate"
channel for internal processing |
| 5 |
"Live"
Input A with Tare |
| 6 |
MAXIMUM
value of Channel 5 since last reset |
| 7 |
MINIMUM
value of Channel 5 since last reset |
| 8 |
"MAX
MINUS MIN" value of Channel 5 since last reset
(= net difference between Channel 6 and Channel 7) |
| 9 |
"Calculate"
channel for internal processing |
| 10 |
"Live"
Input B with Tare |
| 11 |
MAXIMUM
value of Channel 10 since last reset |
| 12 |
MINIMUM
value of Channel 10 since last reset |
| 13 |
"MAX
MINUS MIN" value of Channel 10 since last reset
(= net difference between Channel 11 and Channel 12) |
| 14-16 |
"Calculate"
channels for internal processing |
| 17-19 |
Not
used |
|
|
CHANNEL
RANGES AND SCALING |
Channels
1 and 2 are each initially set for a full-scale transducer range of 120
mV/V |
|
LOGIC
I/O PORTS |
| 0 |
NONLATCHING
OUTPUT: "Live" Input A with Tare (Channel 5) is "LOW"
(i.e., less than "LOL" limit value) |
| 1 |
NONLATCHING
OUTPUT: "Live" Input A with Tare (Channel 5) is "OK"
(i.e., greater than or equal to "LOL" limit
value and less than or equal to "HIL" limit
value) |
| 2 |
NONLATCHING
OUTPUT: "Live" Input A with Tare (Channel 5) is "HIGH"
(i.e., greater than "HIL" limit value) |
| 3 |
NONLATCHING
OUTPUT: "Live" Input B with Tare (Channel 10) is "LOW"
(i.e., less than "LOL" limit value) |
| 4 |
NONLATCHING
OUTPUT: "Live" Input B with Tare (Channel 10) is "OK"
(i.e., greater than or equal to "LOL" limit
value and less than or equal to "HIL" limit
value) |
| 5 |
NONLATCHING
OUTPUT: "Live" Input B with Tare (Channel 10) is "HIGH"
(i.e., greater than "HIL" limit value) |
| 6-7 |
FOR
INTERNAL USE ONLY |
|
|
PROGRAMMABLE
FRONT-PANEL BUTTONS |
| 1 |
"LIVE
DISPLAY, INPUT A": Displays
"Live" Input A with Tare (Channel 5) and lights the
"F1" indicator, which remains lit until Button 2 is
pressed |
| 2 |
"LIVE
DISPLAY, INPUT B": Displays
"Live" Input B with Tare (Channel 10) and lights the
"F2" indicator, which remains lit until Button 1 is
pressed |
| 3 |
"TARE
BOTH INPUTS": Zeroes both Channel 5 and Channel 10 so
that subsequent readings of each channel will represent the
value of the channel minus the existing value of the channel (now
stored as a constant "tare" offset) |
| 4 |
"MAX/MIN/MAX-MIN
STEP" FOR SELECTED INPUT:
If
input A is selected:
If
Channel 5 is currently on display, displays Channel 6
("MAX" of Channel 5) and lights the "F3"
indicator
If
Channel 6 is currently on display, displays Channel 7
("MIN" of Channel 5) and lights the "F4"
indicator
If
Channel 7 is currently on display, displays Channel 8 ("MAX
– MIN" of Channel 5) and lights the "F5"
indicator
If
Channel 8 is currently on display, displays Channel 5
("Live" Input A with Tare)
If
input B is selected:
If
Channel 10 is currently on display, displays Channel 11
("MAX" of Channel 10) and lights the "F3"
indicator
If
Channel 11 is currently on display, displays Channel 12
("MIN" of Channel 10) and lights the "F4"
indicator
If
Channel 12 is currently on display, displays Channel 13
("MAX – MIN" of Channel 10) and lights the
"F5" indicator
If
Channel 13 is currently on display, displays Channel 10
("Live" Input B with Tare)
|
| 5 |
"MAX/MIN
RESET, BOTH INPUTS": Resets the "MAX-" and
"MIN-"measuring functions of Channels 6, 7, 11, and 12 |
|
|
PROGRAMMABLE
FRONT-PANEL INDICATORS |
| 1 |
F1 |
(above
Button 1) |
| 2 |
F2 |
(above
Button 2)—NOT USED |
| 3 |
F3 |
(above
Button 3) |
| 4 |
F4 |
(above
Button 4) |
| 5 |
F5 |
(above
Button 5) |
| 6 |
milli/in |
(bottom
unit legend) |
| 7 |
inches |
(middle
unit legend)—INITIALLY LIT |
| 8 |
mm |
(top
unit legend) |
|
|
"LOGO"
FOR OPTIONAL 10P80D/10P25D
DISPLAY |
4032
STANDARD |
|
MISCELLANEOUS
SETUP PARAMETERS |
See
All Models |
|
Model
4040
Single-Channel Frequency Instrument
[Back
] |
|
SCANNED
DATA CHANNELS |
| 1 |
Not
used (THIS CHANNEL CANNOT BE USED IN ANY 4040 CONFIGURATION) |
| 2 |
"Live"
Frequency Input |
| 3 |
Not
used |
| 4 |
"Calculate"
channel for internal processing |
| 5 |
"Live"
Input with Tare |
| 6 |
MAXIMUM
value of Channel 5 since last reset |
| 7 |
MINIMUM
value of Channel 5 since last reset |
| 8 |
"MAX
MINUS MIN" value of Channel 5 since last reset
(= net difference between Channel 6 and Channel 7) |
| 9-13 |
Not
used |
| 14-16 |
"Calculate"
channels for internal processing |
| 17-18 |
Not
used |
| 19 |
ANALOG
OUTPUT (derived from Channel 5) |
|
|
CHANNEL
RANGES AND SCALING |
Channel
2 is initially set for a full-scale transducer range of 32000 Hz
and an input sensitivity range of 100 mV to 15 V; Channel 2's
active low-pass filter is initially set for the response characteristics
given as "3" in the Model 4040
Specifications; the ±10 VDC Analog Output
Channel (No. 19) is initially scaled for 1 mV of output per 10 Hz for
the current reading of Channel 5 |
|
LOGIC
I/O PORTS |
| 0 |
NONLATCHING
OUTPUT: "Live" Input with Tare (Channel 5) is in "BELOW
BARGRAPH" limit zone |
| 1 |
NONLATCHING
OUTPUT: "Live" Input with Tare (Channel 5) is in LOWER
"DANGER" limit zone |
| 2 |
NONLATCHING
OUTPUT: "Live" Input with Tare (Channel 5) is in LOWER
"CAUTION" limit zone |
| 3 |
NONLATCHING
OUTPUT: "Live" Input with Tare (Channel 5) is in SAFETY
(OK) limit zone |
| 4 |
NONLATCHING
OUTPUT: "Live" Input with Tare (Channel 5) is in UPPER
"CAUTION" limit zone |
| 5 |
NONLATCHING
OUTPUT: "Live" Input with Tare (Channel 5) is in UPPER
"DANGER" limit zone |
| 6 |
NONLATCHING
OUTPUT: "Live" Input with Tare (Channel 5) is in "ABOVE
BARGRAPH" limit zone |
| 7 |
Not
used |
|
|
PROGRAMMABLE
FRONT-PANEL BUTTONS |
| 1 |
Not
used |
| 2 |
"LIVE
DISPLAY": Displays
"Live" Input with Tare (Channel 5)* |
| 3 |
"TARE":
Zeroes Channel 5 so that subsequent readings of Channel 5 will
represent the value of Channel 2 ("Live" Input) minus
the existing value of Channel 2 (now stored as a constant
"tare" offset) |
| 4 |
"MAX/MIN/MAX-MIN
STEP":
If
Channel 5 is currently on display, displays Channel 6
("MAX" of Channel 5) and lights the "F3"
indicator
If
Channel 6 is currently on display, displays Channel 7
("MIN" of Channel 5) and lights the "F4"
indicator
If
Channel 7 is currently on display, displays Channel 8 ("MAX
– MIN" of Channel 5) and lights the "F5"
indicator
If
Channel 8 is currently on display, displays Channel 5
("Live" Input with Tare) and lights the "F2"
indicator
|
| 5 |
"MAX/MIN
RESET": Resets the "MAX-" and
"MIN-"measuring functions of Channels 6 and 7,
respectively |
|
|
PROGRAMMABLE
FRONT-PANEL INDICATORS |
| 1 |
F1 |
(above
Button 1)—NOT USED |
| 2 |
F2* |
(above
Button 2) |
| 3 |
F3 |
(above
Button 3) |
| 4 |
F4 |
(above
Button 4) |
| 5 |
F5 |
(above
Button 5) |
| 6 |
RPM |
(bottom
unit legend) |
| 7 |
Hz |
(middle
unit legend)—INITIALLY LIT |
| 8 |
kHz |
(top
unit legend) |
|
|
"LOGO"
FOR OPTIONAL 10P80D/10P25D
DISPLAY |
4040
STANDARD |
|
MISCELLANEOUS
SETUP PARAMETERS |
See
All Models |
|
*
Under the 4040 standard configuration, the "F2" indicator will
always be ON when the instrument is in "RUN-TIME" mode. |
|
Model
4060
Single-Channel DC/AC Voltage Instrument
[Back
] |
|
SCANNED
DATA CHANNELS |
| 1 |
"Live"
DC/AC Voltage Input |
| 2-3 |
Not
used |
| 4 |
"Calculate"
channel for internal processing |
| 5 |
"Live"
Input with Tare |
| 6 |
MAXIMUM
value of Channel 5 since last reset |
| 7 |
MINIMUM
value of Channel 5 since last reset |
| 8 |
"MAX
MINUS MIN" value of Channel 5 since last reset
(= net difference between Channel 6 and Channel 7) |
| 9-13 |
Not
used |
| 14-16 |
"Calculate"
channels for internal processing |
| 17-18 |
Not
used |
| 19 |
ANALOG
OUTPUT (derived from Channel 5) |
|
|
CHANNEL
RANGES AND SCALING |
Channel
1 is initially set for a full-scale input range of ±10 VDC; the ±10 VDC
Analog Output Channel (No. 19) is initially scaled for 1 mV of output
per 1 mV of input for the current reading of Channel 5 |
|
LOGIC
I/O PORTS |
| 0 |
NONLATCHING
OUTPUT: "Live" Input with Tare (Channel 5) is in "BELOW
BARGRAPH" limit zone |
| 1 |
NONLATCHING
OUTPUT: "Live" Input with Tare (Channel 5) is in LOWER
"DANGER" limit zone |
| 2 |
NONLATCHING
OUTPUT: "Live" Input with Tare (Channel 5) is in LOWER
"CAUTION" limit zone |
| 3 |
NONLATCHING
OUTPUT: "Live" Input with Tare (Channel 5) is in SAFETY
(OK) limit zone |
| 4 |
NONLATCHING
OUTPUT: "Live" Input with Tare (Channel 5) is in UPPER
"CAUTION" limit zone |
| 5 |
NONLATCHING
OUTPUT: "Live" Input with Tare (Channel 5) is in UPPER
"DANGER" limit zone |
| 6 |
NONLATCHING
OUTPUT: "Live" Input with Tare (Channel 5) is in "ABOVE
BARGRAPH" limit zone |
| 7 |
Not
used |
|
|
PROGRAMMABLE
FRONT-PANEL BUTTONS |
| 1 |
"LIVE
DISPLAY": Displays
"Live" Input with Tare (Channel 5) and lights the
"F1" indicator |
| 2 |
Not
used |
| 3 |
"TARE":
Zeroes Channel 5 so that subsequent readings of Channel 5 will
represent the value of Channel 1 ("Live" Input) minus
the existing value of Channel 1 (now stored as a constant
"tare" offset) |
| 4 |
"MAX/MIN/MAX-MIN
STEP":
If
Channel 5 is currently on display, displays Channel 6
("MAX" of Channel 5) and lights the "F3"
indicator
If
Channel 6 is currently on display, displays Channel 7
("MIN" of Channel 5) and lights the "F4"
indicator
If
Channel 7 is currently on display, displays Channel 8 ("MAX
– MIN" of Channel 5) and lights the "F5"
indicator
If
Channel 8 is currently on display, displays Channel 5
("Live" Input with Tare) and lights the "F2"
indicator
|
| 5 |
"MAX/MIN
RESET": Resets the "MAX-" and
"MIN-"measuring functions of Channels 6 and 7,
respectively |
|
|
PROGRAMMABLE
FRONT-PANEL INDICATORS |
| 1 |
F1 |
(above
Button 1) |
| 2 |
F2 |
(above
Button 2)—NOT USED |
| 3 |
F3 |
(above
Button 3) |
| 4 |
F4 |
(above
Button 4) |
| 5 |
F5 |
(above
Button 5) |
| 6 |
°F |
(bottom
unit legend) |
| 7 |
Amps |
(middle
unit legend) |
| 8 |
Volts |
(top
unit legend)—INITIALLY LIT |
|
|
"LOGO"
FOR OPTIONAL 10P80D/10P25D
DISPLAY |
4060
STANDARD |
|
MISCELLANEOUS
SETUP PARAMETERS |
See
All Models |
|
Model
4062
Two-Channel DC Voltage Instrument
[Back
] |
|
SCANNED
DATA CHANNELS |
| 1 |
"Live"
DC Voltage Input A |
| 2 |
"Live"
DC Voltage Input B |
| 3 |
Not
used |
| 4 |
"Calculate"
channel for internal processing |
| 5 |
"Live"
Input A with Tare |
| 6 |
MAXIMUM
value of Channel 5 since last reset |
| 7 |
MINIMUM
value of Channel 5 since last reset |
| 8 |
"MAX
MINUS MIN" value of Channel 5 since last reset
(= net difference between Channel 6 and Channel 7) |
| 9 |
"Calculate"
channel for internal processing |
| 10 |
"Live"
Input B with Tare |
| 11 |
MAXIMUM
value of Channel 10 since last reset |
| 12 |
MINIMUM
value of Channel 10 since last reset |
| 13 |
"MAX
MINUS MIN" value of Channel 10 since last reset
(= net difference between Channel 11 and Channel 12) |
| 14-16 |
"Calculate"
channels for internal processing |
| 17-19 |
Not
used |
|
|
CHANNEL
RANGES AND SCALING |
Channels
1 and 2 are each initially set for a full-scale input range of ±10 VDC |
|
LOGIC
I/O PORTS |
| 0 |
NONLATCHING
OUTPUT: "Live" Input A with Tare (Channel 5) is "LOW"
(i.e., less than "LOL" limit value) |
| 1 |
NONLATCHING
OUTPUT: "Live" Input A with Tare (Channel 5) is "OK"
(i.e., greater than or equal to "LOL" limit
value and less than or equal to "HIL" limit
value) |
| 2 |
NONLATCHING
OUTPUT: "Live" Input A with Tare (Channel 5) is "HIGH"
(i.e., greater than "HIL" limit value) |
| 3 |
NONLATCHING
OUTPUT: "Live" Input B with Tare (Channel 10) is "LOW"
(i.e., less than "LOL" limit value) |
| 4 |
NONLATCHING
OUTPUT: "Live" Input B with Tare (Channel 10) is "OK"
(i.e., greater than or equal to "LOL" limit
value and less than or equal to "HIL" limit
value) |
| 5 |
NONLATCHING
OUTPUT: "Live" Input B with Tare (Channel 10) is "HIGH"
(i.e., greater than "HIL" limit value) |
| 6-7 |
FOR
INTERNAL USE ONLY |
|
|
PROGRAMMABLE
FRONT-PANEL BUTTONS |
| 1 |
"LIVE
DISPLAY, INPUT A": Displays
"Live" Input A with Tare (Channel 5) and lights the
"F1" indicator, which remains lit until Button 2 is
pressed |
| 2 |
"LIVE
DISPLAY, INPUT B": Displays
"Live" Input B with Tare (Channel 10) and lights the
"F2" indicator, which remains lit until Button 1 is
pressed |
| 3 |
"TARE
BOTH INPUTS": Zeroes both Channel 5 and Channel 10 so
that subsequent readings of each channel will represent the
value of the channel minus the existing value of the channel (now
stored as a constant "tare" offset) |
| 4 |
"MAX/MIN/MAX-MIN
STEP" FOR SELECTED INPUT:
If
input A is selected:
If
Channel 5 is currently on display, displays Channel 6
("MAX" of Channel 5) and lights the "F3"
indicator
If
Channel 6 is currently on display, displays Channel 7
("MIN" of Channel 5) and lights the "F4"
indicator
If
Channel 7 is currently on display, displays Channel 8 ("MAX
– MIN" of Channel 5) and lights the "F5"
indicator
If
Channel 8 is currently on display, displays Channel 5
("Live" Input A with Tare)
If
input B is selected:
If
Channel 10 is currently on display, displays Channel 11
("MAX" of Channel 10) and lights the "F3"
indicator
If
Channel 11 is currently on display, displays Channel 12
("MIN" of Channel 10) and lights the "F4"
indicator
If
Channel 12 is currently on display, displays Channel 13
("MAX – MIN" of Channel 10) and lights the
"F5" indicator
If
Channel 13 is currently on display, displays Channel 10
("Live" Input B with Tare)
|
| 5 |
"MAX/MIN
RESET, BOTH INPUTS": Resets the "MAX-" and
"MIN-"measuring functions of Channels 6, 7, 11, and 12 |
|
|
PROGRAMMABLE
FRONT-PANEL INDICATORS |
| 1 |
F1 |
(above
Button 1) |
| 2 |
F2 |
(above
Button 2) |
| 3 |
F3 |
(above
Button 3) |
| 4 |
F4 |
(above
Button 4) |
| 5 |
F5 |
(above
Button 5) |
| 6 |
| | |