DC Voltage Meter

Model 2160

Used as a direct-reading DC voltmeter, this Digital Panel Meter (DPM) model provides a full-scale readout of ±20,000 counts (selectable fixed zero or active least significant digit) and five full-scale voltage ranges/resolutions (see Specifications).  Accuracy is 99.99% of full scale ± 1 count. To minimize the load on the voltage signal, a high input impedance is provided (up to 1 GΩ for the 200.00-mV and 2.000-V ranges).  The maximum voltage which can be applied on the 20, 200, and 660 V-DC range is 660 V-AC.

The model-numbering system is given in the Specifications table, below.

The meter can be used with external current shunts (as shown in the figure), which typically produce 50 mV or 100 mV at their rated maximum current.  Scaling from millivolts to amperes for a specific shunt is easily accomplished from the front panel of the meter.  The scalable readout is five full digits up to ±99,999 counts.  Since the voltage signal from a current shunt can be noisy, the meter provides a selectable, adaptive moving average digital filter (see Digital Panel Meters (DPM’s). 

All voltage ranges are calibrated at the factory, with calibration factors for each range stored in internal EEPROM.  This allows ranges to be changed in the field without having to recalibrate the meter.

As with all 2000 Series DPM’s, the peak value of the input signal is automatically captured and may be displayed via front-panel push button or a control signal received at the rear connector (since the last meter reset).  Data readings and outputs can be separately selected to be either filtered or unfiltered.  See Digital Panel Meters (DPM’s) for a full description of these and other standard DPM features.

2000 Series options applying to the DC voltage meter include

Isolated Relay Outputs

Isolated Analog Output

RS232 or RS485 Interface

BCD Digital Interface

Low AC/DC Power


DC Voltage Meter Specifications  [Top ]

(Click here for 2000 Series General Specifications)

Model
Number

DC Voltage
Range

Resolution

Input Ohms

Error ± 1 Count

2160-002

200.00 mV

10 μV

1 GΩ

0.01 % full scale

2160-2

2.0000 V

100 μV

1 GΩ

0.01 % full scale

2160-20

20.000 V

1 mV

1 MΩ

0.01 % full scale

2160-200

200.00 V

10 mV

1 MΩ

0.01 % full scale

2160-660

660.0 V

100 mV

1 MΩ

0.03 % full scale

All DC Voltage Models

Span Temperature Coefficient

±0.003% of reading/°C

Zero Temperature Coefficient

0.1 count/°C

Normal-Mode Rejection at 50/60 Hz

90 dB with minimum digital filtering

Common-Mode Rejection from DC to 60 Hz

130 dB

Maximum Applied Voltage

660 VAC for 20, 200, and 660 V ranges; 126 VAC for other ranges

[Top ]
 
 