U700

U700

 

Heavy Current Transducer AC voltage difference, arithmetic, with power supply

 

 

Electrical transducer for arithmetical AC voltage difference

U554

U554

 

RMS value measurement, with different characteristics

 

 

Measuring transducer for the conversion of sinusoidal or distorted alternating voltage into an output signal which is proportional to the measured value.

Depending upon the variant, the crucial portion of the measuring range can be extended at the beginning or the end (various characteristics). The less crucial or non-crucial portion is suppressed.

U553

U553

 

RMS value measurement, with power supply

 

 

Measuring transducer for the transformation of sinusoidal or distorted alternating voltage - with power supply terminal.

U543

U543

 

Transducer for Alternating Voltage, self powered

 

 

Measuring transducer for the transformation of sinusoidal alternating voltage, self-powered.

U539

U539

 

 Transducer for Alternating Voltage with power supply

 

 

Measuring transducer for the transformation of sinusoidal alternating voltage, with power supply terminal.

P600

P600

 

Heavy Current Transducer AC and DC mixed currents

 

 

Measuring transducer for the conversion of active power of undulatory voltage and current (containing AC and DC components) into an output signal which is proportional to the measured value.

Q531

Q531

 

Heavy Current Transducer for reactive power

 

 

Measuring transducer for the conversion of reactive power in single phase alternating current or 3-phase systems with balanced or unbalanced load.

A load-independent direct current or direct voltage is used as an output signal, which is proportional to the measured reactive power value.

P530

P530

 

Heavy Current Transducer active power

 

 

Measuring transducer for the conversion of active power in single phase alternating current or 3-phase systems with balanced or unbalanced load.

A load-independent direct current or direct voltage is used as an output signal, which is proportional to the measured active power value.

M563

M563

 

Heavy Current Transducer programmable, with 3 analog outputs, RS 232

 

 

For simultaneously acquiring 3 freely selectable measurands of an electrical power system. 3 analog outputs, RS232.

M562

M562

 

Heavy Current Transducer programmable, with 2 analog outputs, RS 232

 

 

For simultaneously acquiring 2 freely selectable measurands of an electrical power system. 2 analog outputs, RS232.