General
DC "LCM" Specifications [Top
]
(See
also the statement
on LVDT specifications)
|
|
Supply
Requirements, SINGLE* |
+20
to +40 VDC, 25 mA (for standard output) |
|
Supply
Requirements, DUAL |
±10
to ±20 VDC, 25 mA (for standard output) |
|
Armature |
CAPTIVE
(GUIDED) |
|
Linearity
(% error of full scale, worst case) |
±0.5%** |
|
Standard
Output (in/out) |
±5
VDC and/or ±5 VDC (+5%, - 0%)*** |
|
Output
Load (minimum) |
For
+20 to
+40 VDC Power: 20 kΩ
For ±10
to ±20 VDC Power: 2 kΩ |
|
Output
Ripple |
30
mV peak-to-peak |
|
Output
Bandwidth (electrical) |
200
Hz (flat) |
|
Output
Impedance |
2
Ω |
|
Zero
Temperature Coefficient |
±0.01%
of full scale/°C (±0.005% of full scale/°F) |
|
Span
Temperature Coefficient |
±0.03%
of full scale/°C (±0.015% of full scale/°F) |
|
Operating
Temperature Range |
-40°
C to +70° C (-40° F to +158° F) (for standard output) |
|
Operating
Pressure |
150
psi, maximum**** |
|
Electrical
Termination |
Connector
with 16 ft. (5 m) lead (options available) |
|
*
Must be floating with respect to output.
** ±0.25% and ±0.1% linearity are optional on some models (contact
the factory for details).
*** Some electrical termination choices have insufficient conductors
for both output forms. For 4-20 mA and 0-10 V output
options, contact the
factory.
**** Ratings up to 3000 psi available with cable options (contact
the factory for details). |