The
short-stroke Models DS200B and DS500 each have a threaded mounting shank and
locking nut to allow secure, precise positioning in a simple mounting
fixture. For a long-stroke "locking nut" LVDT, see
the Model DS2000.
The coil is epoxy-encapsulated and magnetically shielded,
and the spring-loaded probe terminates in a hardened steel tip, rounded
and polished, which is readily replaceable (see the optional Model
106 Contact Tip, below). An optional rubber boot is also
available, for protection of the probe shaft from fluids and abrasive
materials. (See also the Model 115C
Calibration Kit, which may be used with the short-stroke
"locking nut" LVDT's).
Combining
optimal electrical properties with rugged stainless-steel construction,
these instruments can tolerate years of hard industrial use with no
appreciable loss of precision. Typical applications include
in-process gaging control, creep test recording, structural deflection
measurement, actuator and tool position feedback, dilatometry, strip
thickness measurement, and much more.
Full
Specifications are given below.
Go
to LVDT SELECTION GUIDE
|
Model
DS200B
(dimensions
given in inches / cm)
|
|

|
|
Model
DS500
(dimensions
given in inches / cm)
|
|

|
Short-Stroke
"Locking Nut" Specifications [Top
]
(See also
the statement
on LVDT specifications)
|
|
Linear
Range |
Model
DS200B: ±0.10 in. (±2.5 mm)
Model DS500: ±0.250 in. (±6.35 mm) |
|
Excitation |
Model
DS200B: 1 to 5 VAC (RMS) at 2 to 10 kHz
Model DS500: 2 to 10 VAC (RMS) at 0.06 to 10 kHz* |
|
Armature |
SPRING-EXTENDED |
|
Linearity** |
Model
DS200B: ±0.2% of full scale
Model DS500: ±0.25% of full scale |
|
Sensitivity |
Model
DS200B: 1.8 mV/V/0.001", nominal
Model DS500: 1.0 mV/V/0.001", nominal |
|
Operating
Temperature Range |
Model
DS200B: -20°
C to +125° C (-4° F to +257° F)
Model DS500: -40°
C to +100° C (-40° F to +212° F) |
|
* With excitation below
0.4 kHz, primary voltage should not exceed 3 V.
** Minimum characteristics at 5 kHz excitation for DS200B; at 3 kHz for
DS500. |
|