SEARCH

Products
Index

See List

Selection Guide

Applications

Support

Downloads

Reference

Contact Us

HOME

2000 Series
3000 Series
3KPlus Series
3500 Series
4000 Series
4500 Series
5D Series
5M Series
System 10
MeasuringPad
SPS6000
Cards
Transducers
DC Power SYSKON
Software


[Top

    

 

 

Go to Summary of Instrument Capabilities

Go to Instrument Models for Specific Transducers

Versatile Instrument Intelligence Coupled with Outstanding Measurement Accuracy

The ultimate quality of any electronic measurement depends on how the "raw" measurement signal is handled.  Based on over 47 years' experience in the field of ANALOG SIGNAL CONDITIONING, Daytronic instruments perform all required conditioning tasks—including per-channel analog and digital filtering, A/D conversion, scaling, and linearizing—to ensure true, noise-free, drift-free measurement results, even in the face of substantial dynamic content.

Each instrument's conditioning characteristics are optimized for a particular type of transducer input (see Instrument Models for Specific Transducers, below). 

These "intelligent" instruments do much more than just signal conditioning.  Except for the 5D Series of simple conditioning "blocks," each instrument series is capable of evaluating acquired data and initiating necessary actions for REAL-TIME PROCESS CONTROL.

The more sophisticated 4000 Series instruments can also perform a wide range of SIGNAL PROCESSING functions, including cross-channel calculations for ON-LINE SPC.  In addition, they can be easily programmed by the operator to automatically execute a sequence of standard functions on detection of a given process condition or event.

2000 Series, 3KPlus Sereis, 3500 Series, and 4000 Series instruments can serve as high-speed COMPUTER OR PLC "FRONT ENDS"—in both single-node and multinode (network) environments.  As such, they are completely "STAND-ALONE."  Each instrument is independently responsible for all of its own local data acquisition and control tasks, providing the supervisory host device with finished measurement answers whenever this data is requested.

Go to
Summary of Daytronic

System Capabilities


Summary of Instrument Capabilities  [Top ]

 

Signal Conditioning and Data Display

Real-Time Signal Processing and Process Control

Data Communications

Programmability, Operability, and Security

Table Legend:

S

Standard for ALL models

SS

Standard for SOME models

O

Optional for ALL models

OS

Optional for SOME models

Signal Conditioning and Data Display  [Back ]

 

5D
Series

5M
Series
2000
Series
3000
Series
3KPlus
Series
3500
Series
4000 & 4500
Series

Analog Signal Conditioning
with Multipole Low-Pass Active Filtering and Regulated, Remotely Sensed Excitation

S

S

  S S S S

Concurrent Slope A/D Conversion

 

  S1        

Microprocessor-Based 16-Bit A/D Conversion

 

      S S S

TRANSDUCER INPUTS Accommodated
(see Instrument Models for Specific Transducers):

THERMOCOUPLE

 

     

PLATINUM RTD (100 Ω)

 

         

LVDT & Variable Reluctance

 

SHAFT ENCODER (Quadrature)

 

         

FREQUENCY (Pulse, RPM, etc.)

DC VOLTAGE

DC CURRENT

 

     

AC VOLTAGE (RMS)

 

       

AC CURRENT (RMS)

 

         

DC-EXCITED STRAIN GAGE

AC-EXCITED STRAIN GAGE

 

Multiple Transducer Inputs

 

  SS       SS

Selectable Analog Filtering

S

S   SS S SS SS

Selectable Digital Filtering

 

  S   S S S

Internal Custom Linearization

 

  OS     S S

Front-Panel Digital Indication

 

  S SS S S S

Front-Panel Bargraph Data and Limit-Value Display

 

          S

Real-Time Signal Processing and Process Control  [Back ]

 

5D
Series

5M
Series

2000
Series
3000
Series
3KPlus
Series
3500
Series
4000 & 4500
Series

Continuous Limit Monitoring 
with Isolated Logic Control Outputs

 

  O SS S S S

Front-Panel Annunciation of Limit Status

 

  O SS S S S

Programmable Limit Hysteresis

 

  O   S S  

"Live" Analog Output (± 0 to 5 VDC)

S

S   S2 S S3 S3

"Live" Analog Output (± 0 to 10 VDC)

 

S O   S   S3

"Live" Analog Output (CURRENT)

 

S O OS S    

Real-Time Analog Peak Capture

 

    OS   SS SS

Digital Peak Capture and Hold ("MAX/MIN")

 

  S   S SS S

Digital Track and Hold

 

      S S S

Real-Time Math Processing (including Constants)

 

  OS       S

Auto-Zero / Auto-Tare Capability

 

  S   S S S

Counter or Counter/Timer Functions

 

  SS       S

Real-Time SPC Capability

 

          SS

Programmable Logic I/O

 

          S

Internal Electromechanical and/or Solid-State Relays

 

  O OS S    

Automatic Bit-Controlled Command Execution

 

          S

Data Communications  [Back ]

 

5D
Series

5M
Series
2000
Series
3000
Series
3KPlus
Series
3500
Series
4000 & 4500
Series

RS232 Data Communications

S4

  O   S S S

RS485 (Network) Data Communications

S4

  O     S SS
OS

RS422 and IEEE-488 Data Communications

 

        O O

Ethernet Communications

 

        O

Formattable Serial-ASCII Data Transmissions

 

  O     S S

"Time-Coherent" Serial-ASCII Data Transmissions

 

          S

Programmability, Operability, and Security  [Back ]

 

5D
Series

5M
Series
2000
Series
3000
Series
3KPlus
Series
3500
Series
4000 & 4500
Series

Front-Panel Setup and Run-Time Operation

 

S S S S S S

Setup via Keyboard and/or External Computer/Terminal

 

  O   O O O

Setup via Configuration Software

S

  O   O   OS

Run-Time Operation via Keyboard and/or External Computer/Terminal

 

      O O O

Configuration Security

 

  S   S S S

User-Programmable Front-Panel Buttons and Annunciators

 

S         S

DC-Powered Operation

S

S O O S   OS

Software for Network Management, Data Display and Communications, and/or Other Utilities

 

  O     O O

1

Includes ISOLATED SELECTABLE EXCITATION.  [Back ]

2

Multiple frequency-dependent outputs available for most models.  GALVANIC ISOLATED OUTPUTS optional for some 3000 models.  [Back ]

3

Voltage output is scalable by the user. 4500 output is +/- 5 Vdc [Back ]

4

Configuration commands and responses only.  [Back ]


Instrument Models for Specific Transducers
[Top ]

NOTE: Where the instrument model accepts multiple inputs of the given transducer type, the number of inputs is indicated in parentheses following the model number

 

Thermocouples

100-Ω Platinum RTD's

LVDT's & Variable Reluctance Transducers

Shaft Encoders ("A," "B," and "Z" Signals)

Frequency Sources

DC Voltage Sources

AC (RMS) Voltage Sources

DC Current Sources (4-20 mA)

AC (RMS) Current Sources

DC-Excited Strain Gage Transducers

AC-Excited Strain Gage Transducers

Temperature

    Thermocouples  [Back ]

 

5D
Series

5M
Series
2000
Series
3000
Series
3KPlus
Series
3500
Series
4000 & 4500
Series

Type B

             

Type E

   

5M14

2113-1
(°C)
2113-2
(°F)
       

Type J

   

5M14

2110-1
(°C)
2110-2
(°F)
       

Type K

   

5M14

2111-1
(°C)
2111-2
(°F)
       

Type N

   

5M14

2114-1
(°C)
2114-2
(°F)
       

Type R

   

5M14

2116-1
(°C)
2116-2
(°F)
       

Type S

   

5M14

2115-1
(°C)
2115-2
(°F)
       

Type T

   

5M14

2112-1
(°C)
2112-2
(°F)
       
    100-Ω Platinum RTD's  [Back ]

 

5D
Series

5M
Series
2000
Series
3000
Series
3KPlus
Series
3500
Series
4000 & 4500
Series

DIN 
(α = 0.00385)

    2118-1
(°C)
2118-2
(°F)
       

ANSI 
(α = 0.003925)

    2119-1
(°C)
2119-2
(°F)
       

Displacement

    LVDT's and Variable Reluctance Transducers  [Back ]

 

5D
Series

5M
Series
2000
Series
3000
Series
3KPlus
Series
3500
Series
4000 & 4500
Series

 

5D30 5M30   3130
3230
3330
3KPlus-30 3530

4030,4032  
4K/SPC-30
4K/SPC-32

 4500 (4)

    Shaft Encoders ("A," "B," and "Z" Signals)  [Back ]

 

5D
Series

5M
Series
2000
Series
3000
Series
3KPlus
Series
3500
Series
4000 & 4500
Series

 

    2135        

Frequency

    Frequency Sources*  [Back ]

 

5D
Series

5M
Series
2000
Series
3000
Series
3KPlus
Series
3500
Series
4000 & 4500
Series

 

5D40 5M40 2140 (2)
2140R (2)
3140A
3240A
3340A
3KPLUS-40 3540 4040
4K/HP**

4500 (4)

* E.g., AC waveforms, tachometer pickups, turbine flowmeters, transistor or logic-circuit drivers, "zero-velocity" sensors, etc.

** The Model 4K/HP Horsepower Instrument has both a FREQUENCY input channel (for measurement of RPM) and an AC STRAIN GAGE input channel (for measurement of TORQUE).

Voltage / Current

    Voltage Sources  [Back ]

 

5D
Series

5M
Series
2000
Series
3000
Series
3KPlus
Series
3500
Series
4000 & 4500
Series

DC Voltage

5D64
5M64
2160
2162*
2162X*
3163
3263
3363
3KPlus-64 3560 4060
4062
(2)
4K/SPC-60
4K/SPC-62 (2)

4500 (4)

AC (RMS)
Voltage

    2168       4060
4K/SPC-60

 

4500 (4)

 

* The Models 2162 and 2162X are dedicated primarily to the measurement of 4-20 mA PROCESS SIGNALS, but may also be used to produce scalable VOLTAGE readout from strain gages, or in potentiometer follower applications.

    Current Sources  [Back ]

 

5D
Series

5M
Series
2000
Series
3000
Series
3KPlus
Series
3500
Series
4000 & 4500
Series

DC Current
(4-20 mA)

5D64 ***
5M64
2161
2162
2162X
  3KPlus-64 *** 3560  *** 4060
4062
(2) ***

4500 (4)

 

 

AC (RMS) Current

    2169        

Force

    Strain Gage Transducers  [Back ]

 

5D
Series

5M
Series
2000
Series
3000
Series
3KPlus
Series
3500
Series
4000 & 4500
Series

DC-Excited

5D70 5M70

IL-70

2170
2170X

2162*
2162X*
3170
3270
3370
TM3
3KPlus-70 3570 4077
4K/SPC-77
4K/WT-77
4K/PM-77

4500 (4)

AC-Excited

5D78 5M78   3178
3278
3378
3KPlus-78 3578 4078
4K/HP**

4500 (4)

* The Models 2162 and 2162X are dedicated primarily to the measurement of 4-20 mA PROCESS SIGNALS, but may also be used to produce scalable VOLTAGE readout from strain gages, or in potentiometer follower applications.

** The Model 4K/HP Horsepower Instrument has both a FREQUENCY input channel (for measurement of RPM) and an AC STRAIN GAGE input channel (for measurement of TORQUE).

*** Requires external input shunt resistor added, typically 250 Ohm.

 

[Top ]


© 1996, 2010 Daytronic Corporation