SEARCH
Products
Index
See
List
Selection
Guide
Applications
Support
Downloads
Reference
Contact
Us
HOME
[Top
]
|
|

Versatile
Instrument Intelligence Coupled with Outstanding Measurement Accuracy
The
ultimate quality of any electronic measurement depends on how the
"raw" measurement signal is handled. Based on over 47 years'
experience in the field of ANALOG SIGNAL CONDITIONING, Daytronic
instruments perform all required conditioning tasks—including per-channel
analog and digital filtering, A/D conversion, scaling, and linearizing—to
ensure true, noise-free, drift-free measurement results, even in the face of
substantial dynamic content.
Each
instrument's conditioning characteristics are optimized for a particular type
of transducer input (see Instrument Models for Specific
Transducers, below).
These "intelligent" instruments do much more than just signal
conditioning. Except for the 5D Series of simple conditioning
"blocks," each instrument series is capable of evaluating acquired
data and initiating necessary actions for REAL-TIME PROCESS CONTROL.
The
more sophisticated 4000 Series instruments can also perform a wide range
of SIGNAL PROCESSING functions, including cross-channel calculations for ON-LINE
SPC. In addition, they can be easily programmed by the operator to
automatically execute a sequence of standard functions on detection of a given
process condition or event.
2000
Series, 3KPlus Sereis, 3500 Series, and 4000 Series instruments can serve as
high-speed COMPUTER OR PLC "FRONT ENDS"—in both single-node
and multinode (network) environments. As such, they are completely
"STAND-ALONE." Each instrument is independently responsible for
all of its own local data acquisition and control tasks, providing the
supervisory host device with finished measurement answers whenever this
data is requested.
|

|
Go to
Summary of Daytronic
System
Capabilities |

Summary
of Instrument Capabilities
[Top
]
|
|
|
|
Table
Legend:
|
|
S |
Standard
for ALL models |
|
SS |
Standard
for SOME models |
|
O |
Optional
for ALL models |
|
OS |
Optional
for SOME models |
|
|
|
Signal
Conditioning and Data Display
[Back
]
|
|
|
5D
Series |
5M
Series |
2000
Series |
3000
Series |
3KPlus
Series |
3500
Series |
4000
& 4500
Series |
|
Analog
Signal Conditioning
with Multipole Low-Pass Active Filtering and Regulated, Remotely Sensed
Excitation |
S |
S |
|
S |
S |
S |
S |
|
Concurrent
Slope A/D Conversion |
|
|
S1 |
|
|
|
|
|
Microprocessor-Based
16-Bit A/D Conversion |
|
|
|
|
S |
S |
S |
|
TRANSDUCER
INPUTS Accommodated
(see Instrument
Models for Specific Transducers): |
|
THERMOCOUPLE |
|
● |
● |
|
|
|
|
|
PLATINUM
RTD (100 Ω) |
|
|
● |
|
|
|
|
|
LVDT
& Variable Reluctance |
● |
● |
|
● |
● |
● |
● |
|
SHAFT
ENCODER (Quadrature) |
|
|
● |
|
|
|
|
|
FREQUENCY
(Pulse, RPM, etc.) |
● |
● |
● |
● |
● |
● |
● |
|
DC
VOLTAGE |
● |
● |
● |
● |
● |
● |
● |
|
DC
CURRENT |
|
● |
● |
|
● |
|
|
|
AC
VOLTAGE (RMS) |
|
|
● |
|
|
|
● |
|
AC
CURRENT (RMS) |
|
|
● |
|
|
|
|
|
DC-EXCITED
STRAIN GAGE |
● |
● |
● |
● |
● |
● |
● |
|
AC-EXCITED
STRAIN GAGE |
● |
● |
|
● |
● |
● |
● |
|
Multiple
Transducer Inputs
|
|
|
SS |
|
|
|
SS |
|
Selectable
Analog Filtering |
S |
S |
|
SS |
S |
SS |
SS |
|
Selectable
Digital Filtering |
|
|
S |
|
S |
S |
S |
|
Internal
Custom Linearization |
|
|
OS |
|
|
S |
S |
|
Front-Panel
Digital Indication |
|
|
S |
SS |
S |
S |
S |
|
Front-Panel
Bargraph Data and Limit-Value Display |
|
|
|
|
|
|
S |
|
Real-Time
Signal Processing and Process Control
[Back
]
|
|
|
5D
Series |
5M
Series |
2000
Series |
3000
Series |
3KPlus
Series |
3500
Series |
4000
& 4500
Series |
|
Continuous
Limit Monitoring
with Isolated Logic Control Outputs |
|
|
O |
SS |
S |
S |
S |
|
Front-Panel
Annunciation of Limit Status |
|
|
O |
SS |
S |
S |
S |
|
Programmable
Limit Hysteresis |
|
|
O |
|
S |
S |
|
|
"Live"
Analog Output (±
0 to 5 VDC) |
S |
S |
|
S2 |
S |
S3 |
S3 |
|
"Live"
Analog Output (±
0 to 10 VDC) |
|
S |
O |
|
S |
|
S3 |
|
"Live"
Analog Output (CURRENT) |
|
S |
O |
OS |
S |
|
|
|
Real-Time
Analog Peak Capture |
|
|
|
OS |
|
SS |
SS |
|
Digital
Peak Capture and Hold ("MAX/MIN") |
|
|
S |
|
S |
SS |
S |
|
Digital
Track and Hold |
|
|
|
|
S |
S |
S |
|
Real-Time
Math Processing (including Constants) |
|
|
OS |
|
|
|
S |
|
Auto-Zero
/ Auto-Tare Capability |
|
|
S |
|
S |
S |
S |
|
Counter
or Counter/Timer Functions |
|
|
SS |
|
|
|
S |
|
Real-Time
SPC Capability |
|
|
|
|
|
|
SS |
|
Programmable
Logic I/O |
|
|
|
|
|
|
S |
|
Internal
Electromechanical and/or Solid-State Relays |
|
|
O |
OS |
S |
|
|
|
Automatic
Bit-Controlled Command Execution |
|
|
|
|
|
|
S |
|
Data
Communications
[Back
]
|
|
|
5D
Series |
5M
Series |
2000
Series |
3000
Series |
3KPlus
Series |
3500
Series |
4000
& 4500
Series |
|
RS232
Data Communications |
S4 |
|
O |
|
S |
S |
S |
|
RS485
(Network) Data Communications |
S4 |
|
O |
|
|
S |
SS
OS |
|
RS422
and IEEE-488 Data Communications |
|
|
|
|
|
O |
O |
|
Ethernet Communications |
|
|
|
|
|
|
O |
|
Formattable
Serial-ASCII Data Transmissions |
|
|
O |
|
|
S |
S |
|
"Time-Coherent"
Serial-ASCII Data Transmissions |
|
|
|
|
|
|
S |
|
Programmability,
Operability, and Security
[Back
]
|
|
|
5D
Series |
5M
Series |
2000
Series |
3000
Series |
3KPlus
Series |
3500
Series |
4000
& 4500
Series |
|
Front-Panel
Setup and Run-Time Operation |
|
S |
S |
S |
S |
S |
S |
|
Setup
via Keyboard and/or External Computer/Terminal |
|
|
O |
|
O |
O |
O |
|
Setup
via Configuration Software |
S |
|
O |
|
O |
|
OS |
|
Run-Time
Operation via Keyboard and/or External Computer/Terminal |
|
|
|
|
O |
O |
O |
|
Configuration
Security |
|
|
S |
|
S |
S |
S |
|
User-Programmable
Front-Panel Buttons and Annunciators |
|
S |
|
|
|
|
S |
|
DC-Powered
Operation |
S |
S |
O |
O |
S |
|
OS |
|
Software
for Network Management, Data Display and Communications, and/or Other
Utilities |
|
|
O |
|
|
O |
O |
|
1 |
Includes
ISOLATED SELECTABLE EXCITATION. [Back ]
|
|
2 |
Multiple
frequency-dependent outputs available for most models.
GALVANIC ISOLATED OUTPUTS optional for some 3000 models. [Back
]
|
|
3 |
Voltage
output is scalable by the user. 4500 output is +/- 5 Vdc [Back ]
|
|
4 |
Configuration
commands and responses only. [Back ]
|
|
Instrument
Models for Specific Transducers
[Top
]
|
|
NOTE:
Where the instrument model accepts multiple inputs of the given
transducer type, the number of inputs is indicated in parentheses
following the model number
|
|
Temperature
|
Thermocouples
[Back
]
|
|
|
|
5D
Series |
5M
Series |
2000
Series |
3000
Series |
3KPlus
Series |
3500
Series |
4000 & 4500
Series |
|
Type
B |
|
|
|
|
|
|
|
|
Type
E |
|
5M14 |
2113-1
(°C)
2113-2
(°F) |
|
|
|
|
|
Type
J |
|
5M14 |
2110-1
(°C)
2110-2
(°F) |
|
|
|
|
|
Type
K |
|
5M14 |
2111-1
(°C)
2111-2
(°F) |
|
|
|
|
|
Type
N |
|
5M14 |
2114-1
(°C)
2114-2
(°F) |
|
|
|
|
|
Type
R |
|
5M14 |
2116-1
(°C)
2116-2
(°F) |
|
|
|
|
|
Type
S |
|
5M14 |
2115-1
(°C)
2115-2
(°F) |
|
|
|
|
|
Type
T |
|
5M14 |
2112-1
(°C)
2112-2
(°F) |
|
|
|
|
100-Ω
Platinum RTD's
[Back
]
|
|
|
|
5D
Series |
5M
Series |
2000
Series |
3000
Series |
3KPlus
Series |
3500
Series |
4000 & 4500
Series |
|
DIN
(α = 0.00385) |
|
|
2118-1
(°C)
2118-2
(°F) |
|
|
|
|
|
ANSI
(α = 0.003925) |
|
|
2119-1
(°C)
2119-2
(°F) |
|
|
|
|
|
Displacement
|
LVDT's and Variable Reluctance Transducers
[Back
]
|
|
|
|
5D
Series |
5M
Series |
2000
Series |
3000
Series |
3KPlus
Series |
3500
Series |
4000 & 4500
Series |
|
|
5D30 |
5M30 |
|
3130
3230
3330 |
3KPlus-30 |
3530 |
4030,4032
4K/SPC-30
4K/SPC-32
4500
(4)
|
Shaft
Encoders ("A," "B," and "Z" Signals)
[Back
]
|
|
|
|
5D
Series |
5M
Series |
2000
Series |
3000
Series |
3KPlus
Series |
3500
Series |
4000 & 4500
Series |
|
|
|
|
2135 |
|
|
|
|
|
Frequency
|
|
|
|
|
5D
Series |
5M
Series |
2000
Series |
3000
Series |
3KPlus
Series |
3500
Series |
4000 & 4500
Series |
|
|
5D40 |
5M40 |
2140
(2)
2140R
(2) |
3140A
3240A
3340A |
3KPLUS-40 |
3540 |
4040
4K/HP**
4500
(4)
|
|
*
E.g., AC waveforms, tachometer pickups, turbine flowmeters, transistor or
logic-circuit drivers, "zero-velocity" sensors, etc.
** The Model 4K/HP Horsepower Instrument has both a FREQUENCY input
channel (for measurement of RPM) and an AC STRAIN GAGE input channel (for
measurement of TORQUE). |
|
Voltage
/ Current
|
|
|
|
|
5D
Series |
5M
Series |
2000
Series |
3000
Series |
3KPlus
Series |
3500
Series |
4000 & 4500
Series |
|
DC
Voltage |
5D64 |
5M64
|
2160
2162*
2162X* |
3163
3263
3363 |
3KPlus-64 |
3560 |
4060
4062
(2)
4K/SPC-60
4K/SPC-62 (2)
4500
(4)
|
|
AC
(RMS)
Voltage |
|
|
2168 |
|
|
|
4060
4K/SPC-60
4500
(4)
|
|
*
The Models 2162 and 2162X are dedicated primarily to the
measurement of 4-20 mA PROCESS SIGNALS, but may also be used to produce
scalable VOLTAGE readout from strain gages, or in potentiometer follower
applications. |
|
|
|
|
5D
Series |
5M
Series |
2000
Series |
3000
Series |
3KPlus
Series |
3500
Series |
4000 & 4500
Series |
|
DC
Current
(4-20 mA) |
5D64
*** |
5M64
|
2161
2162
2162X |
|
3KPlus-64
*** |
3560
*** |
4060
4062
(2) ***
4500
(4)
|
|
AC
(RMS) Current |
|
|
2169 |
|
|
|
|
|
Force
|
Strain
Gage Transducers
[Back
]
|
|
|
|
5D
Series |
5M
Series |
2000
Series |
3000
Series |
3KPlus
Series |
3500
Series |
4000 & 4500
Series |
|
DC-Excited |
5D70 |
5M70
IL-70
|
2170
2170X
2162*
2162X* |
3170
3270
3370
TM3 |
3KPlus-70 |
3570 |
4077
4K/SPC-77
4K/WT-77
4K/PM-77
4500
(4) |
|
AC-Excited |
5D78 |
5M78 |
|
3178
3278
3378 |
3KPlus-78 |
3578 |
4078
4K/HP**
4500
(4) |
|
*
The Models 2162 and 2162X are dedicated primarily to the
measurement of 4-20 mA PROCESS SIGNALS, but may also be used to produce
scalable VOLTAGE readout from strain gages, or in potentiometer follower
applications.
** The Model 4K/HP Horsepower Instrument has both a FREQUENCY input
channel (for measurement of RPM) and an AC STRAIN GAGE input channel (for
measurement of TORQUE). ***
Requires external input shunt resistor added, typically 250 Ohm. |
[Top
]
|