A universal PC/PLC front-end system,
soon to be available for demos and orders

(contact the factory for more information)

Using Daytronic's 5D Series Signal Conditioner Modules, each DataNode16 is a software-configurable multichannel system for bringing low-level sensor signals to multiple devices—including PC's, PLC's, local SCADA networks, and even web browser interfaces.

The low-noise rackmount chassis hosts up to 16 mixed 5D conditioners to create a highly accurate and stable front-end device for the acquisition, recording, and transmission of data—and one that performs at remarkably high speed.

DataNode16's internal processor scans, scales, and digitizes 5D measurements at 16-bit resolution and a rate of 64 kHz (4 kHz per channel).  

Its fully open communications platform provides fast, seamless transfer of finished-answer data over a single cable, using the standard Modbus addressable protocol.  It's ideal for real-time data exchange with OPC client applications.  And it can receive simple ASCII mnemonic commands from any of its host devices for purposes of interrogation, on-the-fly reconfiguration, and local control.

DataNode16 also features

Up to 64 internal cross-channel calculations, including MAX, MIN, and AVERAGE

Continuous HI/LO limit monitoring of selected data channels and calculations

Two independent history recorders, with programmable channel lists and store conditions, operating in either circular (FIFO) or fill-and-stop mode; store conditions include time intervals, input triggers, and limit violation

 

 

DataNode16 General Specifications

Dimensions

Fits 3U 19-inch rack
Height: 3.479 in.
Width: Front: 18.944 in.; Rear: 17.320 in.
Depth: 10.34 in.

Operating Temperature Range

-10° C to 70° C (14° F to 158° F)

Operating Relative Humidity

5% to 95%, noncondensing

Power Requirements

85 to 264 VAC RMS; 1.4 A

Power Output

Isolated 24 VDC, 100 mA (via front-panel terminal, for powering digital triggers; see diagram, above)

Analog Inputs

Individual sensor inputs of up to 16 standard 5D Series Signal Conditioner Modules installed in the DataNode16

NOTE:
"V-" and "S-version" models may not be used.

Processor Speed

133 MHz

A/D Conversion

16-bit

Scan Rate

64 kHz; 4 kHz per channel

Memory

64MB SDRAM; 32MB Flash Disc-on-Chip

Analog Outputs (Isolated)

One per installed conditioner module; filtered ± 0 to 5 VDC (this is module "Output A"; see 5D Series General Specifications)

Digital Inputs

Four isolated logic-level triggers for history recording, via front-panel terminals (see diagram, above); active low

Isolation

500 VAC (10 mA cutoff, 1 minute)

Voltage Range

0 to +24 VDC

Overvoltage Protection

Up to ±48 VDC (36 VAC RMS)

Operating Frequency

100 kHz minimum

Communications

Rear-panel I/O ports for RS232 and RS485 Modbus

Front-Panel Indication

Power, Communications (Modbus activity)

Individual Module Status Indication

Green/Yellow/Red; indicates conditioner module input and communications status (see 5D Series General Specifications for details)

 

Go to

5D Series
Signal Conditioners

3000PLUS
Panel Meter

[Top ]
 

 

© 1996, 2002 Daytronic Corporation