With
this option, a Form 3 instrument can
switch power for control action in all types of open-loop or ON-OFF
closed-loop operations. It may be used, for example, to actuate
alarms or sorting devices, or to start up or shut down external
processes. Both relay types are controlled directly by the unit's
LIMIT VIOLATION outputs.
The
Electromechanical Relay ("R" Option) is ideal for DC or
low-level switching. Two normally open and two normally closed
contacts are rated at 8 amps, 250 V-AC at full resistive load.
Switch lifetime at 1 amp resistive load exceeds 100,000 operations.
The
Solid-State Relay ("S" Option) is suitable for
controlling medium-power AC loads, or for highly repetitive operations
(since its lifetime at full resistive load exceeds 10,000,000
operations). Its contacts (similar to those of the Electromechanical
Relay) are rated at 3 amps, 250 V-AC at full load. Zero-crossing
circuitry ensures low EMI.
NOTE:
The "R" Option may NOT be used in combination with the
"C," "G," "P," or "S"
Option. The
"S" Option may NOT be used in combination with the
"B," "C," "G," "P," or
"R" Option.
 |
|
This
automatic filling operation uses a Model
3370S DC Strain Gage Conditioner/Indicator/Controller with
internal solid-state relay. The 3370S monitors the container's
weight as it fills. When the maximum weight setpoint is
reached, the HI limit is tripped, the relay is actuated, and the
bin's solenoid valve closes. |
|