5M Series General Specifications

Housing

DIN mount housing; non-removable screw terminals. Plastic

Dimensions

Connections (5M standard models)

The Model 5M I/O CONNECTIONS are via non-removable screw terminals  ( four sets of four connectors) which will

accept wire sizes from AWG 12 to 26. NOTE: The recommended transducer

cabling would be eight wire, individually shielded, twisted pair - wired as indicated per modules data sheet.

Modules with Sense lines must be connected at the transducer (as recommended) or at the 5M module itself

Power Requirements

11- 28 Vdc ; 2 watts Max, typical

Input Overvoltage Protection

Up to 240 VAC rms on all Signal and Excitation lines

ESD Protection

per EN61000-4-2

Analog Filtering

Low pass modified 3-pole Butterworth - selectable low, medium & high settings

Operating Temperature Range

-10° C to 70° C (14° F to 158° F)

Operating Relative Humidity

5% to 95%, noncondensing

Analog Outputs

Filtered ± 0 to 5 Vdc or ±0 to 10 Vdc, 4-12-20 or 4-20 mA (sourcing). Mode is switch selectable with linearity maintained for  20% overrange (in voltage mode only)

 Accuracy

Offset and Gain Stability ±30 ppm/Deg C; vs. time ±10ppm/month: Gain Accuracy is limited to calibration source, 5M14 is ±0.02% of input range

Logic Inputs

Activated with power common to initiate functions such as NULL, SHUNT, CALIBRATION. Specific to Model. 

Status Indicator Light

GREEN

Power supply indicator

YELLOW

Input signal over 20% out of range