5M Series General Specifications
|
Housing |
DIN mount housing; non-removable screw terminals. Plastic |
|
Dimensions |
|
|
Connections (5M standard models) |
The Model 5M I/O CONNECTIONS are via non-removable screw terminals ( four sets of four connectors) which will accept wire sizes from AWG 12 to 26. NOTE: The recommended transducer cabling would be eight wire, individually shielded, twisted pair - wired as indicated per modules data sheet. Modules with Sense lines must be connected at the transducer (as recommended) or at the 5M module itself |
|
Power Requirements |
11- 28 Vdc ; 2 watts Max, typical |
|
Input Overvoltage Protection |
Up to 240 VAC rms on all Signal and Excitation lines |
|
ESD Protection |
per EN61000-4-2 |
|
Analog Filtering |
Low pass modified 3-pole Butterworth - selectable low, medium & high settings |
|
Operating Temperature Range |
-10° C to 70° C (14° F to 158° F) |
|
Operating Relative Humidity |
5% to 95%, noncondensing |
|
Analog Outputs |
Filtered ± 0 to 5 Vdc or ±0 to 10 Vdc, 4-12-20 or 4-20 mA (sourcing). Mode is switch selectable with linearity maintained for 20% overrange (in voltage mode only) |
|
Accuracy |
Offset and Gain Stability ±30 ppm/Deg C; vs. time ±10ppm/month: Gain Accuracy is limited to calibration source, 5M14 is ±0.02% of input range |
|
Logic Inputs |
Activated with power common to initiate functions such as NULL, SHUNT, CALIBRATION. Specific to Model. |
Status Indicator Light |
|
|
GREEN |
Power supply indicator |
|
YELLOW |
Input signal over 20% out of range |